INTRODUCTION
INSTALLATION
CHARGING STATUS OF THE BATTERIES
BATTERIES
This unit is intended for professional use.
Read all the instructions in this manual prior to use.
•
Only use the unit for the purposes for which it is intended.
•
This unit has not been approved for use in commercial transactions.
•
Do not alter or modify the unit.
•
Do not exceed the maximum unit working pressure. See page 7, technical specifications.
•
Use the unit with fluids and solutions which are compatible with the moist parts of the unit. See the
relevant section of the technical specifications.
•
Observe the manufacturer’s safety warnings for the fluids used.
•
The meter has been manufactured with low tolerances in order to ensure high precision over a wide
range of flows and viscosity.
•
Check measurement units counter before first use.
•
In order to save energy the meter switches off automatically after 30 seconds of inactivity. All the
data are stored for recovery once the meter has been restarted.
The meter can be connected to a control gun or installed directly in the distribution line pipe.
It is recommendable to install a cut-off valve before the meter to facilitate its maintenance or repair.
The meter has a ½” NPSM connection at the inlet and outlet.
It also includes an inlet flange and a flange at the outlet with seating for an O-ring seal which enables connection
for the range of guns and original Eurolube accessories.
The meter requires two 1.5 V batteries and size LR 03 as the power supply source. They are housed in a support
which, in conjunction with the lid design, prevents the batteries from being removed accidentally in the event of
impacts or vibrations.
The meter shows the charging status of the batteries on the display.
If the meter does not switch on when pressing the ON/RESET button, or switches off after being pressed,
replace the batteries with new ones.
The location of the batteries is shown in the following figure:
OPERATING MODE
IMPORTANT:
Always read the instructions prior to using for the first time.
HANDLING
1 ON/RESET
Press once only to switch on the meter.
Keep pressed to reset the partial meter or the “Trip” to zero.
2 SELECT
Consecutively press to browse the various functions:
3 On/Off
•
The meter is probably switched off when you wish to use it.
•
Press the ON/RESET button to switch it on (fig. 1). The meter performs a check on the display by
showing all the segments briefly (fig. 2) and then on the display shows a similar status to that shown
(fig. 3).
•
The display shows the partial meter.
•
Although switched off, the meter automatically goes to an On status when detecting fluid flow and
starts to record the quantity released by showing the partial meter.
•
In order to save energy the meter switches off automatically after 30 seconds of inactivity. The
registered data are stored.
4 Fluid release
•
To release fluid, switch on the meter by pressing the ON/RESET button or simply start to release
and the meter will automatically switch on by starting to register the fluid.
•
If, after successive measurements, (fig. 4) you wish to set (fig. 6) the partial meter to zero, hold
down the ON/RESET button for a while (fig. 5).
•
Each unit of volume released increases both the partial meter and the total meter.
•
When the meter switches off, or the batteries are removed, the data of the last measurement taken
are stored.
!
WARNING
BATTERIES OK
BATTERIES HALF CHARGED
BATTERIES EMPTY
REPLACE THE BATTERIES
Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
ELECTRONIC METER
PART NO. (USED IN): 1168803 (16713, 1168385, 16826-01, 16827-01), 1168806 (16813), 1168808 (36720, 36730), 1168809