21
•
EN
OPERATION
The built-in control panel features four operating buttons and a display which shows all operation statuses of the
machine. The control panel allows the user to customize the DMX starting address and output height and switch
on/off the automatic stop of spark output in case of the device tipping over. The machine can be operated with the
wireless or cable remote control. Alternatively, it can be controlled with a DMX controller. DMX control
will take
priority over the manual operation.
Operating buttons
Button
Function
MENU
Selecting menu items
ENTER
Activating spark output manually in “Manual Test” mode
UP / DOWN
Setting values
Status indicators
Display
Function
Heat
The device is warming up
Ready
The device is ready for spark output
Wait
Awaiting next action / spark output disabled via DMX
Clean
Cleaning function via DMX active
Menu items
Display
Function
Addr DMX512
0-512
Adjusting the starting address
Volume Out
1-100%
Adjusting the fountain height
Tip Over
ON/OFF
Activating or deactivating automatic stop of spark output in
case of the device tipping over by more than 45°
Note: The tipping
sensor is a very important protection
mechanism. It should always be activated.
Manual Test
Manual activation of spark output for test purposes with
ENTER button