25
Maintenance
The operator has to make sure that safety-relating and machine-technical installations are to be
inspected by an expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are to be
inspected by a skilled person once a year.
The following points have to be considered during the inspection:
1.
All screws used for installing the device or parts of the device have to be tightly connected and must
not be c
orroded.
2.
There may not be any deformations on housings, fixations and installation spots.
3.
Mechanically moving parts like axles, eyes and others may not show any traces of wearing.
4.
The electric power supply cables must not show any damages or material fatigue.
The LED Pixel Mesh requires alm
ost no m
aintenanc
e. How
ever, you shoul
d keep the unit c
l
ean.
Otherwise, the fixture’s light-output will be significantly reduced.
Disconnect the mains power supply, and
then wipe the cover with a damp cloth. Do not immerse in liquid. Wipe lens clean with glass cleaner and
a soft cloth. Do not use alcohol or solvents. Keep connections clean. Disconnect electric power, and
then wipe the connections with a damp cloth. Make sure connections are thoroughly dry before linking
equipment or supplying electric power.
Troubleshooting
Please check system according to the following steps if the LED Screen can not work normally after
finishing the connection and the power on
:
Trouble Description
Trouble Analysis
Solution
Whole screen
Blackout
The power supply does not work
Power on
LED control software does not turn on.
Setting control software
Transmission line does not connect well
Reconnect transmission
line
Display shows black color
Reset the desktop menu
Frame module power supply does not connect
well or voltage does not match
Make sure the voltage
above 4.75V
Connecting wire between module and
scanning board are above stated length
Cut off the cable line
Screen twinkle
Data wire above the stated length or some
trouble with cable wire
Ensure the cable wire
quality
Connect data wire does not fasten well
Re-plug
Control system out
of control
Unit board has some trouble
Check the module
Display card setting does not correct
Reset the display card
Set the LED control software locked
Set the control software
unlock
Do not increase power supply when increasing
power supply to the module
Add power source to
scanning controller
If you are unable to determine the cause of the problem, do not open the LED Pixel Mesh, as this may