-19-
GB
Visual warnings and possible faults
Causes
Corrective action
3cl
6cl
12cl
6°C
18°C
MESSAGE D’ALERTE
NITROGEN CYLINDER EMPTY
A/ The nitrogen
cylinder is not open
Click the warning message. Check whether the cylinder is open or closed.
Open the nitrogen cylinder if it is closed.
If it is already open, refer to cause B or C
B/The nitrogen
cylinder is empty
Close the cylinder and replace it with a new one (see Chapter 3.3 : Use/
replacement of the empty nitrogen cylinder)
C/The nitrogen
cylinder is not
properly connected
Check the connection of the tube to the nitrogen cylinder.
3cl
6cl
12cl
6°C
18°C
MESSAGE D’ALERTE
NITROGEN LEAK
A wine bottle is not
properly connected
to the machine
or
an articulated head
is in the vertical
position without a
bottle
Contrôler
les 8 bouteilles
connectées à la
machine
Contrôler
la position de
chaque tête de
mise sous vide
Contact after-sales
Click the warning message.
Check all of the bottle necks connected to the
machine.
- Necks not chipped,
- Upper part of the neck does not have any foreign
bodies (cap, cork)
Check the position of each articulated head
The articulated head must remain in an inclined
position: if it is in a vertical position without a bottle,
this will cause nitrogen to leak.
Contact your customer service department if the
problem continues.
3cl
6cl
12cl
6°C
18°C
MESSAGE D’ALERTE
SLOW NITROGEN LEAK
A wine bottle is not
properly connected
to the machine
or
several bottles
have been changed
without informing
the screen
Click the warning message.
This warning is not critical, you can continue to use the appliance normally but it
is essential to resolve the leak quickly to prevent over-consumption of nitrogen.
Contrôler
les 8 bouteilles
connectées à la
machine
Contact after-sales
Check all of the bottle necks connected to the machine.
- Necks not chipped,
- Upper part of the neck does not have any foreign
bodies (cap, cork)
Contact your customer service department if the
problem continues
If several bottles have been changed without providing
this information on the screen, this can cause the “slow
leak warning” message to appear even though there
is not actually a leak. In this case, click the warning
message to make it disappear.
3cl
6cl
12cl
6°C
18°C
MESSAGE D’ALERTE
BOTTLE X EMPTY
Wine bottle empty
Replace with a new bottle
3cl
6cl
12cl
6°C
18°C
MESSAGE D’ALERTE
INSUFFICIENT VOLUME IN BOTTLE X
The measure
requested is more
than the volume
remaining in the
bottle.
Choose a smaller measure or change the bottle.
3. MAINTENANCE PROCEDURES
If you have not taken out a maintenance contract with your exclusive
EuroCave Professional distributor,
it is essential to carry out checks
and maintenance procedures every 6 months in order to guarantee
the longevity of your appliance. Ask your EuroCave Professional
Any work on the refrigerating unit must be carried out by
a qualified refrigeration engineer, who, before restarting,
will have to leak test the circuit. Likewise, any work on the
electrical system will have to be carried out by a qualified
electrician.
VI
OPERATING FAULTS
& WARNING MESSAGES
Содержание Vin au Verre 8.0
Страница 23: ......