-8-
GB
INSTALLING
VIN AU VERRE 8.0
1. SETTING UP THE APPLIANCE
When your appliance is delivered, after unpacking it, check the inside
and outside for signs of damage (dents, buckling…). Open the doors
and check that the appliance is intact (walls, articulated heads…).
If there is a problem, contact your EuroCave Professional retailer.
Transport your appliance to its intended location.
This must:
•
Be open to the outside to allow air circulation (not in a cupboard)
•
Be away from any source of heat
•
Not be too damp: for optimal performance, max. 35°C/85%
relative humidity
•
Have a flat, stable surface
•
Have a power supply (standard outlet, 16 A, earthed with circuit
breaker, 30 mA* (* not applicable to some countries).
Precautions
•
Do not place your appliance in an area likely to flood.
•
Do not place the appliance close to a source of heat or anywhere
the appliance will come into contact with direct sunlight.
•
Prevent water or any other liquid from splashing onto the entire
back section of the appliance.
•
Position your appliance so that there is a minimum space of 5 - 10
cm between the wall and the back wall of your appliance.
•
Arrange the power lead so that it is accessible and does not come
into contact with any of the appliance’s components.
•
Do not obstruct the ventilation inlets at the rear of the appliance.
•
The ventilation inlets must be a minimum distance of 5 cm from
any wall or object.
•
Do not plug several appliances into a multi-socket adaptor and do
not use an extension cord.
Installation
Set the 4 feet independently in such a way as to incline your cabinet
slightly towards the rear by 2 - 3°, in order to allow condensation to
flow out.
Then, unwind the nitrogen cylinder connection tube, located at the back
of the appliance and leave it in place until you connect it up.
Place the 2 condensate collection drip trays underneath the product.
Each tray is inserted into the 2 runners on either side of the product.
2. FLUSH-FITTING THE APPLIANCE
Observe the following instructions:
Dimensions in mm
i
30 mA
1
2
10°C
50°F
35°C
95°F
1035
585
150
50
50
735
785
50
1135
100
90 kg
300
100
6 ° C
16 ° C
3cl
6cl
15cl
III
Flush-fitting conditions:
•
Ensure that there is a 5 cm gap on both sides and above
the product
•
Ensure that there is a 10 cm gap at the back of the product
•
Provide a breather hole on the top of the product
The breather hole must be
•
On the top of the product
•
Next to the edge of the back of the product
•
100 mm from the side edge (on the right-hand side of the
product)
Recommended room temperatures
The unit must be
strong enough to
withstand 90 kg the
weight of the bottles
10°C
50°F
35°C
95°F
1035
585
150
50
50
735
785
50
1135
100
90 kg
300
100
6 ° C
16 ° C
3cl
6cl
15cl
Ensure that there is room
for the power lead and
nitrogen tube to pass
through without suffering
damage.
•
Wait 48 hrs before plugging in your Vin au Verre 8.0.
• When moving or setting up the appliance, never tilt
it more than 45°.
To perfectly align the appliance’s doors horizontally
and correct any unevenness of the surface on which
the appliance will stand, you can tighten or loosen the
front feet with a 19mm key.