22
The LED indicators will help you drill at optimum load:
[image 4-6]
Phase 1 = A
Phase 2 = B
Phase 3 = C
Phase 4 = D
Phase 5
1 blue light
2 blue lights
2 blue lights
1 yellow light
2 blue lights
1 yellow light
1 red light
Flashing red
light + beeping
sound
Load
Optimum load
Acceptable
overload
Close to
overload
Overload limit
exceeded,
motor stops
Slightly increase
feed pressure
when possible
Maintain feed
pressure
Slightly reduce
feed pressure
when possible
Reduce feed
pressure
Reduce feed
pressure
When the motor is in overload (phase 5), the Smart Restart torque control technology
ensures trouble-free continuation of your drilling job. When the feed pressure is reduced, the
machine’s electronics recognize the reduction and the motor continues within a few seconds.
WARNING:
The displayed motor power usage and LED indicators are only an indication of
correct cutting performance. Always keep an eye on the workpiece, tool and machine and
check if the cutting performance is as it should be.
WARNING:
Never touch any potentially moving parts as long as the motor switch is still
switched on!
4.11 Overheat protection
This machine is supplied with an all-time electronic overheat protection. If the temperature of the
motor unit runs up to 70° C (158 °F) the motor unit will stop. After a few minutes it can be started
again. When it is possible to start the motor again, let the motor run idle at full speed for a couple of
minutes to let the motor cool down more in an efficient way.