Storage Conditions
The following requirements are applicable during storage conditions when the product is not
operating:
Requirements
Property
Min.
Max.
Unit
Temperature range
-20
+75
°C
-4
+158
°F
Humidity range
10
90
% RH
Condition (1):
non-condensing
Compliance
Electromagnetic
The product complies with:
●
The European Council EMC Directive 2004/108/EC
●
The Unites States FCC rule 47 CFR 15
It has been tested and found to comply with the following standards:
Radiated emission
Standard
Limit / Level
EN 55022
Class A
FCC 47 CFR 15 Sub-part A
Class A
Immunity
Standard
Description
EN 61000-4-3
Radiated, radio-frequency, electromagnetic field immunity test
EN 61000-4-4
Electrical fast transient/burst immunity test
EN 61000-4-5
Surge immunity test
EN 61000-4-6
Immunity to conducted disturbances, induced by radio-frequency fields
EN 61000-4-11
Voltage dips, short interruptions and voltage variations immunity tests