![Euresys Picolo.net HD1 Скачать руководство пользователя страница 34](http://html1.mh-extra.com/html/euresys/picolo-net-hd1/picolo-net-hd1_getting-started_2436142034.webp)
34
Property
Test condition
Min.
Typ.
Max.
Unit
Full-scale output voltage
10 kΩ load, default gain
1.41
1.48
1.55
V
ptp
Output impedance
1 kHz
470
Ω
Absolute Maximum Ratings
Property
Min.
Typ.
Max.
Unit
DC voltage
-10
+10
V
Exceeding the above limits may irreversibly damage the product.
Alarm Input Port
The alarm input port implements a digital polarity-free non-isolated interface.
It supports the direct connection of single-ended digital drivers operating at TTL, 3V CMOS, 5V
CMOS, and 12V CMOS levels
Operating Characteristics
Property
Min.
Typ.
Max.
Unit
Voltage threshold
1.5
V
Absolute maximum ratings
Property
Min.
Typ.
Max.
Unit
DC voltage
0
20
V
Exceeding the above limits may irreversibly damage the device.