![Euresys Picolo.net HD1 Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/euresys/picolo-net-hd1/picolo-net-hd1_getting-started_2436142020.webp)
20
a.
Connect the Data- and the Data+ signals respectively to the Rx/TxD- (pin 3) and the
Rx/TxD+ (pin 4) outputs of the COM connector 8-pin terminal plug
b.
Connect the GND signal and/or the cable shield to the GND (pin 5 and/or pin 6) of the 8-pin
terminal plug
●
For a RS-232 device:
a.
Connect the GND signal and/or the cable shield to the GND (pin 5 and/or pin 6) of the 8-pin
terminal plug
b.
Connect the Tx output signal to the RxD input (pin 7) of the 8-pin terminal plug
c.
Connect the Rx output signal to the TxD output (pin 8) of the COM 8-pin terminal plug
COM connector
General Purpose I/O
Connect one alarm sensor device and/or one relay-driven device to the GPIO connector via a 4-
pin 3.81 mm pitch terminal plug:
●
To connect one alarm sensor, insert the 2 wires into INA (pin 1) and INB (pin 2) of the 4-pin
plug.
●
To connect one relay-driven device, insert the 2 wires into OUTA (pin 3) and OUTB (pin 4) of
the 4-pin plug.
GPIO connector
The wiring polarity is irrelevant.
Power Input
Risk of damage to the product
Turn off or disconnect the power source before proceeding.
Connect a 12 V DC power source to the POWER IN connector via a 2-pin 3.81 mm pitch terminal
plug:
a.
Connect the GND to the GND input (pin 1) of the 2-pin terminal plug
b.
Connect the +12 V output to the +12 V input (pin 2) of the 2-pin terminal plug
Picolo.net
Getting Started
2. Installing a Picolo.net