50
AC characteristics
Parameter
Min.
Typ.
Max.
Units
Pulse rate
0
100
kHz
Turn-on time
5
µs
Turn-off time
5
µs
Typical switching performance @ 25°C
Current [mA]
Turn ON time [µs]
Turn OFF time [µs]
0.5
2.0
4.8
1.0
2.0
3.9
4.0
2.2
3.3
10
2.3
2.7
40
2.3
2.7
100
2.3
2.7
Logical map
The state of the output port is determined as follows:
Logical State
Output port state
HIGH
The contact switch is closed (ON)
LOW
The contact switch is open (OFF)
Compatible loads
The following loads are compatible with the isolated contact output ports:
●
Any load within the 30 V / 100 mA envelope is accepted. The power originates from an
external power source or alternatively from the power delivered through the 12 V and GND
pins of the I/O connectors.