48
Input Current vs. Input Voltage Characteristics
AC characteristics
Parameter
Min.
Typ.
Max.
Units
Pulse width
10
µs
Pulse rate
0
50
kHz
Logical map
The state of the port is reported as follows:
Input current
Logical State
IIN > 1 mA
HIGH
IIN < 1 mA
LOW
Unconnected input port
LOW
Compatible drivers and receivers
The following drivers are compatible with the isolated current-sense inputs:
●
Totem-pole LVTTL, TTL, 5 V CMOS drivers
●
RS-422 Differential line drivers
●
Potential free contact, solid-state relay, or opto-isolators
●
12 V and 24 V signaling voltages are also accepted
NOTE
□
The +12 V power supply on the I/O connector(s) can be used for
powering drivers requiring a power supply.
□
No external resistors are required. However, to obtain the best noise
immunity with 12 V and 24 V signaling, it is recommended to insert a
series resistor in the circuit. The recommended resistor values are:
4.7k Ohms for 12 V signaling and 10k Ohms for 24 V signaling.