22
Board Status LED
Board status LED indicator states
LED
state
Symbol
Meaning
Off
No power.
The board is not powered or the power distribution network is not
functional.
FPGA NOK.
The FPGA start-up procedure is not completed.
The normal completion time
is around 100 milliseconds.
Solid
green
Board status OK.
The main power distribution network is operational and the FPGA start-up
procedure has successfully completed.
Solid
red
Board status NOK.
Possible causes are:
●
There is no power delivered on the +12 V rail of the PCI Express
connector slot
●
At least one power converter of the main power distribution network is
unable to operate properly.
This might be caused by excessive
temperature due to inadequate board cooling, accidental short-circuits
having blown one (or more) protection fuses, inappropriate supply
voltages, etc.
Coaxlink
Hardware Manual
Содержание Coaxlink 1629