FC972 Remote
4/7
Can Buss Termination
Can Buss Termination must be done on either the SY982 Sync or FC972
Remote. Lack of termination or double termination may result in communication
errors in the system.
Software Setup
Setting the IP address
Each frame controller on a network must have a unique IP, subnet mask and
gate way (if necessary). During configuration, FC972 modules are addressed as
IP address: 192.168.0.150 (and upward), subnet: 255.255.255.0, gateway
192.168.0.1. To change this, there are two principal methods, via RS232 or via
network.
IP address setup via RS232
1. Connect a PCs RS232 (COMx) via a 1:1 cable to the module and run
a terminal program e.g. Hyperterminal or Minicom (115,200-8-N-1)
and press ENTER :
2. Select “2: Network configuration” and make the appropriate settings
3. Select “4: Reboot”
IP address setup via network
1. Connect the FC972 via an Ethernet cross over cable to a PC.
2. Change the network setting of the PC to the address room of the
default IP address of the unit, subnet 255.255.0.0.
Note: You will find the factory default IP address on a label at the
controller module (see Installation). This address is valid only if the
module is initialized to factory default settings using the front-panel INIT
button. See Operation.
FC972 Remote