Euphonix Modular I/O Configuration Guide
Product Data Sheets
61
3/3
Frame position
The SY983 must be installed in one of the red colored fitting rails at the rear of
the frame, close to the mains connectors. In the case of Master / Slave operation,
both SY983 modules must be place here.
Redundant clock sources
The SY983 Sync module is the central clocking source for the Modular I/O
system. It provides all necessary clocks for proper system operation and can be
synchronized internally or externally. A Modular I/O frame can be equipped with
a second (redundant) SY983. Both sync modules must be installed in the red
“reserved” slots on the rear-plane of the frame.
Use the MASTER/SLAVE DIP to set the first SY983 as MASTER and the second
unit to SLAVE. Both SY983 modules should be locked to the same external sync
source. In this mode, both modules generate all clocks all the time with the
SLAVE disconnected from the frame sync busses. A red LED “SLAVE“ normally
lights indicating the SLAVE module is in “ready” status.
The SLAVE unit permanently watches the correct LOCK status of the MASTER.
In case of failure of the MASTER (losing external sync or fault on the module
hardware) the SLAVE unit takes over and continues clocking the frame. The red
SLAVE-LED blinks in this condition. If the MASTER unit returns to lock (new
sync signal, or new hardware) it automatically takes over the clock busses and
the SLAVE returns to the “ready” status.
Setting the frame ID
Set DEV0, DEV1, & DEV2 to “ON.”
DEV X
On the master sync module, set DEVX to “ON.” On a redundant sync module,
set to “OFF.”
Can Buss Termination
Can Buss Termination must be done on either the SY983 Sync or FC972
Remote. Lack of termination or double termination may result in communication
errors in the system. Typically, CAN Termination is done on the FC972.
Operation
Select a clock source by turning the front-pane; source rotary encoder with a
small screw driver. A LED display shows the respective combination of clock
frequency and sync mode.
The web interface shows the status of each sync module and provides access to
all configuration settings. In case of a severe sync problem, the Frame Controller
can send a SNMP trap and or activate a GPO. A higher-ranking monitoring
system may poll the status of the sync module(s) via SNMP
SY983 Sync