Euphonix Modular I/O Configuration Guide
Product Description
11
(configurable via DIP switched, some disassembly required
to access).
Connections, Power, Space, Weight
Power (IEEEx2); PSU: autosensing (100~240vAC, 50/60Hz);
input current (internal 5vDC rail at maximum load): 1.5A @
99vAC, 700mA @ 207vAC; output: 5v@12A usable power,
3RU, front-plane module space: 72HP, rear-plane space:
76HP (typical module width: 4HP/8HP), audio connections
will appear on front and rear in typical configurations.
Weight: ~5.3kg.
1.1.2 IO94 Stagebox Frame
General Description
The IO94 is a 3RU single-sided frame with built-in dual-
redundant PSUs. The frame contains 19 rear-plane slots.
Rear-plane slots 1-4 are “reserved” for the sync source
module(s). Other modules may be fitted here also. Sync,
control, and audio busses are shared by all slots in the frame.
Connections, Power, Space, Weight
Power (IEEEx2); PSU: autosensing (100~240vAC, 50/60Hz);
input current (internal 5vDC rail at maximum load): 3A @
99vAC, 1.5A @ 207vAC; output: 5v@20A usable power,
3RU, rear-plane space: 76HP (typical module width:
4HP/8HP), audio connections will appear rear only. Weight:
~5.3kg.
1.1.3 IO95 Modular Frame (for local-side redundant MADI-over-Fiber
interface)
General Description
The IO95 is a 3RU double-sided frame with removable dual-
redundant PSUs capable of delivering 5v@12A of usable
power. The frame contains 19 rear-plane slots and 18 front-
plane slots for modules. Rear-plane slots 1-4 are “reserved”
for the sync source module(s). Other modules may be fitted
here also. Sync and control busses are shared by all slots in
the frame.