EUCHNER NZ.VZ-VS Series Скачать руководство пользователя страница 8

8

Operating Instructions

Safety Switches NZ.VZ-…VS

Indicator LED (only with switching element 511, 528, 538)
L060

L110

L220

AC/DC  12…60 V

AC 

110 V  (±15 %)

AC 

230 V  (±15 %)

Rated insulation voltage
NZ1VZ…/NZ2VZ‑5…

NZ2VZ‑2…/NZ2VZ‑3…

U

i

 = 250 V

U

i

 = 50 V

Rated impulse withstand voltage
NZ1VZ…/NZ2VZ‑5…

NZ2VZ‑2…/NZ2VZ‑3…

U

imp

 = 2.5 kV

U

imp

 = 1.5 kV

Conditional short‑circuit 

current

100 A

Switching voltage, min.,

at 10 mA

12 V

Utilization category acc. to EN 60947‑5‑1
NZ.VZ‑511…

AC‑15 6 A 230 V / 

DC‑13 6 A 24 V

NZ1VZ…/NZ2VZ‑5…

AC‑15 4 A 230 V / 

DC‑13 4 A 24 V

NZ2VZ‑2…/NZ2VZ‑3…

AC‑15 4 A 50 V / 

DC‑13 4 A 24 V

Switching current, min.,  

at 24 V

NZ.VZ‑511…

NZ.VZ‑…

10 mA

1 mA

Short circuit protection 

(control circuit fuse)  

acc. to IEC 60269‑1

4 A gG

Convent. thermal current I

th

4 A

Solenoid operating voltage/solenoid power consumption
VSE03/VSM03

DC 19V/AC 24V  (+10%/‑15%) 8 W

VSE04/VSM04

DC 24V 

(+10%/‑15%) 8 W

VSE05/VSM05

DC 41V/AC 48V  (+10%/‑15%) 8 W

VSE06/VSM06

DC 48V 

(+10%/‑15%) 8 W

VSE07/VSM07

DC 97V/AC 110V  (+10%/‑15%) 8 W

VSE09/VSM09

DC 196V/AC 230V (+10%/‑15%) 10 W

Duty cycle

100 %

Plug connector for solenoid locking
DC

Order no. 028345

AC

Order no. 028338

Locking force F

max

 

(in locked position)

F

S

 = 2000 N

Locking force F

Zh

 

acc. to EN ISO 14119

(F

Zh

 =

 F

max

) = 1500 N

 

 1.3

Limitations at ambient temperature above +70 … +80 °C

Utilization category

NZ2VZ‑5… 

NZ2VZ‑2…/NZ2VZ‑3…

AC‑15 2 A 230 V / 

DC‑13 2 A 24 V

AC‑15 2 A 50 V / 

DC‑13 2 A 24 V

Short circuit protection 

(control circuit fuse)  

acc. to IEC 60269‑1

2 A gG

Convent. thermal current I

th

2 A

Reliability values  

acc. to EN ISO 13849-1
depending on the switching 

current at 24 V DC

At DC‑13  100 mA/24 V

≤ 0.1 A

B

10D

ES511

ES528H/ES538H

4.5 x 10

6

SK2121H/SK2131H/

SK3131H

4.5 x 10

6

Fig. 5:  Safety switch series NZ.VZ-…VS.

Fig. 6:  Plug connector for solenoid locking

U

M

U   AC

N

U   DC

N

The actuator must be fully 

inserted in the safety switch 

before voltage is applied to 

the locking solenoid.

Fig. 4:  Switching elements with switching functions and connector assignment

511

528

538

3131

2131

2121

View of connection side 

on the safety switch

1

6

5 4

3

2

9

11

10

5

4

6

3

7

2

8

1

Terminal assign‑

ment of plug 

connector 

SR6

Terminal assign‑

ment, plug connec‑

tor 

SR11

Ordinal numbers of switching 

contacts

Fig. 5a

Fig. 5b

View of connection side 

on the safety switch

Guard closed and 

locked

Guard closed and 

not locked

Guard open

Содержание NZ.VZ-VS Series

Страница 1: ...n des Betätigers und beim Aktivieren Entsperren der Zuhaltung wird der Zuhaltebolzen bewegt Dabei werden die Schaltkon takte betätigt Bei blockiertem Zuhaltebolzen Zuhaltung aktiv kann der Betätiger nicht aus dem Schalterkopf gezogen werden Konstruktionsbedingt kann die Zuhaltung nur aktiviert werden wenn die Schutzeinrichtung geschlossen ist Fehlschließsicherung Die Konstruktion des Sicherheitssc...

Страница 2: ...zeinrichtung muss so lange zugehalten bleiben bis keine Gefahr für den Prozess mehr besteht Maschinenfunktion darf sich nicht starten lassen solange die Zuhaltung entsperrt ist Wiederholen Sie die Schritte 2 4 für jede Schutz einrichtung einzeln Kontrolle und Wartung WARNUNG Gefahr von schweren Verletzungen durch den Verlust der Sicherheitsfunktion f Bei Beschädigung oder Verschleiß muss der gesam...

Страница 3: ...38 Zuhaltekraft Fmax in Sperrstellung FS 2000 N Zuhaltekraft FZh nach EN ISO 14119 FZh Fmax 1500 N 1 3 Einschränkungen bei Umgebungstemperatur größer 70 80 C Gebrauchskategorie NZ2VZ 5 NZ2VZ 2 NZ2VZ 3 AC 15 2 A 230 V DC 13 2 A 24 V AC 15 2 A 50 V DC 13 2 A 24 V Kurzschlussschutz Steuer sicherung nach IEC 60269 1 2 A gG Konv thermischer Strom Ith 2 A Zuverlässigkeitswerte nach EN ISO 13849 1 in Abh...

Страница 4: ...g zu gewährleisten Zum Ausschalten muss der Betätiger mindestens bis Punkt a zurückge zogen werden gesteckt 100 Bild 8 Maßzeichnung NZ1VZ VSH mit Leitungseinführung a Leerlaufweg Betätiger ist im Führungsschlitz jedoch ohne eine Funktion aus zulösen b Schaltvorgang beendet Betätiger muss bis zu diesem Punkt eingeführt werden um eine sichere Schaltung zu gewährleisten Zum Ausschalten muss der Betät...

Страница 5: ...TAETIGER Z G 1000 RADIUSBETAETIGER Z R 400 RADIUSBETAETIGER Z L 400 RADIUSBETAETIGER Z C2194 200 RADIUSBETAETIGER Z U 165 RADIUSBETAETIGER Z O 165 Bild 10 Minimale Türradien Radiusbetätiger Z L C2194 Z R C2194 Radiusbetätiger Z L Z R Radiusbetätiger Z U Z O 23 10 31 70 10 7 30 35 29 5 5 5 Ø5 5 8 16 14 28 20 40 50 20 92 Ø5 5 8 16 14 28 20 40 50 20 92 Z L Z R 40 50 4 23 29 70 Ø 5 5 14 Z L Z R Z U Z ...

Страница 6: ...he actuator and on the activation release of the guard locking During this process the switching contacts are actuated If the guard locking pin is blocked guard locking active the actuator cannot be pulled out of the switch head For design reasons guard locking can be activated only when the guard is closed prevention of inadvertent locking position faulty closure protection The safety switch is d...

Страница 7: ...p the machine function and release guard locking The guard must remain locked until the process is no longer at risk It must not be possible to start the machine function as long as guard locking is released Repeat steps 2 4 for each guard Inspection and service WARNING Danger of severe injuries due to the loss of the safety function f If damage or wear is found the complete switch and actuator as...

Страница 8: ...id locking DC Order no 028345 AC Order no 028338 Locking force Fmax in locked position FS 2000 N Locking force FZh acc to EN ISO 14119 FZh Fmax 1500 N 1 3 Limitations at ambient temperature above 70 80 C Utilization category NZ2VZ 5 NZ2VZ 2 NZ2VZ 3 AC 15 2 A 230 V DC 13 2 A 24 V AC 15 2 A 50 V DC 13 2 A 24 V Short circuit protection control circuit fuse acc to IEC 60269 1 2 A gG Convent thermal cu...

Страница 9: ... to ensure safe switching The actuator must be withdrawn at least to point a for switching off Inserted 100 Fig 8 Dimension drawing for NZ1VZ VSH with cable entry a Travel without operation Actuator is in the guide slot but a function is not triggered b Switching operation com pleted Actuator must be inserted to this point to ensure safe switching The actuator must be withdrawn at least to point a...

Страница 10: ...ructions Actuator Door radius min mm ACTUATOR Z G 1000 HINGED ACTUATOR Z R 400 HINGED ACTUATOR Z L 400 HINGED ACTUATOR Z C2194 200 HINGED ACTUATOR Z U 165 HINGED ACTUATOR Z O 165 Fig 10 Minimum door radii Hinged actuator Z L C2194 Z R C2194 Hinged actuator Z L Z R Hinged actuator Z U Z O 23 10 31 70 10 7 30 35 29 5 5 5 Ø5 5 8 16 14 28 20 40 50 20 92 Ø5 5 8 16 14 28 20 40 50 20 92 Z L Z R 40 50 4 2...

Страница 11: ...positif d interverrouillage provoque le déplacement du doigt Ceci a pour effet d action ner les contacts de commutation Lorsque le doigt de verrouillage est bloqué inter verrouillage actif il est impossible de retirer la languette de la tête de l interrupteur Par concep tion l interverrouillage ne peut être activé que si le protecteur est fermé sécurité contre les erreurs de fermeture L interrupte...

Страница 12: ...r 3 Démarrer la fonction de la machine Il ne doit pas être possible de débloquer le système d interverrouillage tant que la fonction dangereuse de la machine est active 4 Arrêter la fonction de la machine et débloquer le système d interverrouillage Le protecteur doit rester verrouillé tant que le risque pour le process subsiste Il ne doit pas être possible de démarrer la fonction de la machine tan...

Страница 13: ...W Facteur de marche ED 100 Connecteur pour verrouillage par électroaimant DC Code article 028345 AC Code article 028338 Force de retenue Fmax en position consignée FS 2000 N Force de retenue FZh selon EN ISO 14119 FZh Fmax 1500 N 1 3 Limitations à une température ambiante sup à 70 80 C Catégorie d emploi NZ2VZ 5 NZ2VZ 2 NZ2VZ 3 AC 15 2 A 230 V DC 13 2 A 24 V AC 15 2 A 50 V DC 13 2 A 24 V Protectio...

Страница 14: ...ne commutation sûre Pour la mise hors circuit la languette doit être retirée au moins jusqu au point a connecté 100 Fig 8 Dimensions NZ1VZ VSH avec entrée de câble a Course d approche Introduction de la languette sans manœuvre de contact b Manœuvre terminée La languette doit être introduite jusqu à ce point afin de garantir une commutation sûre Pour la mise hors circuit la languette doit être reti...

Страница 15: ...ANGUETTE Z G 1000 LANGUETTE ARTICULEE Z R 400 LANGUETTE ARTICULEE Z L 400 LANGUETTE ARTI CULEE Z C2194 200 LANGUETTE ARTICULEE Z U 165 LANGUETTE ARTICULEE Z O 165 Fig 10 Rayons de porte minimum Languette articulée Z L C2194 Z R C2194 Languette articulée Z L Z R Languette articulée Z U Z O 23 10 31 70 10 7 30 35 29 5 5 5 Ø5 5 8 16 14 28 20 40 50 20 92 Ø5 5 8 16 14 28 20 40 50 20 92 Z L Z R 40 50 4 ...

Страница 16: ...queo que se encargan de bloquear liberar el perno de bloqueo Al introducir o extraer el actuador y al activar o des activar el bloqueo el perno de bloqueo se mueve Durante este proceso se accionan los contactos de conmutación Cuando el perno de bloqueo está bloqueado bloqueo activo el actuador no puede sacarse de la cabeza del interruptor Debido a su diseño el bloqueo solo puede activarse si el re...

Страница 17: ...e un funcionamiento peligroso 4 Detenga el funcionamiento de la máquina y desbloquee el bloqueo El resguardo debe permanecer bloqueado hasta que ya no haya ningún peligro para el proceso La máquina no debe poder ponerse en marcha mientras el bloqueo esté desbloqueado Repita los pasos 2 4 para cada resguardo Controles y mantenimiento ADVERTENCIA Peligro de lesiones graves por pérdida de la función ...

Страница 18: ...ueo DC N º de N º 028345 CA N º de N º 028338 Fuerza de bloqueo Fmáx en posición de bloqueo FS 2000 N Fuerza de bloqueo FZh según EN ISO 14119 FZh Fmáx 1500 N 1 3 Limitaciones a una temperatura ambiental superior a 70 80 C Categoría de uso NZ2VZ 5 NZ2VZ 2 NZ2VZ 3 CA 15 2 A 230 V CC 13 2 A 24 V CA 15 2 A 50 V CC 13 2 A 24 V Protección contra cortocircuitos fusible del circuito de control según IEC ...

Страница 19: ...r una conmutación segura Para la desac tivación el actuador debe retraerse al menos hasta el punto a Introducido 100 Fig 8 Plano de dimensiones NZ1VZ VSH con entrada de cable a Recorrido en vacío El actuador está en la ranura guía pero la función no se acciona b Proceso de activación fi nalizado El actuador debe insertarse hasta este punto para garantizar una conmutación segura Para la desac tivac...

Страница 20: ...e instrucciones original Actuador Radio de puerta mín mm ACTUADOR Z G 1000 ACTUADOR RADIAL Z R 400 ACTUADOR RADIAL Z L 400 ACTUADOR RADIAL Z C2194 200 ACTUADOR RADIAL Z U 165 ACTUADOR RADIAL Z O 165 Fig 10 Radios de puerta mínimos Actuador radial Z L C2194 Z R C2194 Actuador radial Z L Z R Actuador radial Z U Z O 23 10 31 70 10 7 30 35 29 5 5 5 Ø5 5 8 16 14 28 20 40 50 20 92 Ø5 5 8 16 14 28 20 40 ...

Отзывы: