Operating Instructions
Light Grids/Light Curtains LCA 2
80
(translation of the original operating instructions) 2504708-03-02/21
11. Technical data
NOTICE
If a data sheet is included with the product, the information on the data sheet applies.
Parameter
LCA 2
Unit
Protective field height
160 – 1,810
mm
Resolutions
30/40/50
mm
Number of beams (light grid)
2/3/4 beams
Usable range (selectable)
0 … 4 (low) / 0 … 12 (high)
m
Type of output
2 semiconductor outputs, p-switching, short circuit-proof
Current consumption
400
mA
Reaction time
3 – 27
ms
Test pulse length
< 100
µs
Operating voltage DC
24 ± 20%
Vcc
Connection
Plug connector M 12 (5-/8-pin)
Max. connectible length
100
m
Operating temperature
-30 … +55
°C
Degree of protection
IP65; IP67
Cross-section dimensions
28 x 30
mm
Signals
1 (transmitter)
2 (receiver)
LED
Mission time
20
years
Reliability values acc. to EN ISO 13849-1
Performance Level
PL c
Category
2
ESPE (DIN EN 61496-1/ 61496-2)
Type 2
PFH
D
See following tables for values