9
2119563-08-07/17 (translation of the original operating instructions)
Operating Instructions
Non-Contact Safety Switch CES-I-AR-.-C04-…
EN
The supplied type label must be affixed on the safety switch.
On use in potentially explosive atmospheres, there is a danger of explosion due to electrical sparks.
Ì
Never connect or disconnect connector when live.
7.1. Technical data of housing guard AM-C-C04-EX-137528
Parameter
Value
Unit
min.
typ.
max.
Housing material
PBT/PC plastic
Dimensions
75 x 30 x 20
mm
Weight
0.02
kg
Ambient temperature
- 25
-
+ 65
°C
Tightening torque of fixing screw in combination with
CES-I-AR-.-C04-…
-
-
60
Ncm
7.1.1. Dimension drawing of housing guard AM-C-C04-EX-137528
F-F
2,8
7,
2
5
20
75
30
32
F
F
7.2. Mounting
1
2
1
Affix ATEX type label
2