Operating Instructions
Non-Contact Safety Switch CES-I-AR-.-C04-…
16
(translation of the original operating instructions) 2119563-08-07/17
9.7. Connector assignment of Y-distributor
M12x1
max. 45
Ø 14,5
Strapping plug 097645
4-pin, plug
(figure similar)
Y-distributor
with connection cable
111696 or 112395
Socket
Plug
Socket
Pin
Function
X2.1
U
B
X2.2
FO1A
X2.3
0 V
X2.4
FO1B
X2.5
RST
Pin
Function
X3.1
U
B
X3.2
FI1A
X3.3
0 V
X3.4
FI1B
X3.5
RST
12
12
097627
45°
15,1
4
8
5
6
3 1
2
7
35,1
20,5
1
2
4
5
3
3
4
2
1
5
M x1
Ø 14,6
M x1
(
)
Y-distributor
097627
Socket
Connector assignment of
safety switch CES-I-AR
(8-pin plug)
and
Y-distributor (8-pin socket)
Pin
Function
X1.1
FI1B
X1.2
U
B
X1.3
FO1A
X1.4
FO1B
X1.5
OD
X1.6
FI1A
X1.7
0 V
X1.8
RST
Plug
Socket
M12x1
44
45
41
15
M12x1
15
15
M12x1
33
A
B
4
8
5
6
3
1
2
7
1
2
4
5
3
3
4
2
1
5
Length l
Order no. Length
l [mm]
111696
200
112395
1,000
Pin
Function
X2.1
U
B
X2.2
FO1A
X2.3
0 V
X2.4
FO1B
X2.5
RST
Pin
Function
X3.1
U
B
X3.2
FI1A
X3.3
0 V
X3.4
FI1B
X3.5
RST