(translation of the original operating instructions) 2119563-08-07/17
12.3. Technical data of actuator CES-A-BDN-06
Parameter
Value
Unit
min.
typ.
max.
Housing material
Macromelt PA-based plastic
Dimensions
26 x
∅
6
mm
Weight
0.005
kg
Ambient temperature
- 40
-
+ 70
°C
Degree of protection acc. to EN IEC 60529
IP67 / IP69K
1)
Installation position
Active face opposite read head
Power supply
Inductive via read head
1) With flush installation
12.3.1. Dimension drawing
Installation options
26
0
+0,5
Ø
30
* min.
30 *
30 *
6,1
0
+0,1
6
* Metal-free zone
Operating
distance
C
A
Approach
direction
CAUTION
Ì
Do not mount at temperatures below 0 °C.
Ì
The actuator can be damaged during mounting.
12.3.2. Switching distances
Operating distance for center offset m = 0
Approach direction
Parameter
Value
Unit
A
min.
typ.
max.
Switch-on distance
-
19
-
mm
Assured switch-on distance s
ao 1)
14
-
-
Switching hysteresis
1)
-
2
-
Assured switch-off distance s
ar
- in x/z direction
- in y direction
-
-
-
-
40
60
1) The values apply to surface installation of the actuator
Approach direction
Parameter
Value
Unit
C
min.
typ.
max.
Switch-on distance
-
15
-
mm
Assured switch-on distance s
ao
1)
10
-
-
Switching hysteresis
1)
-
2
-
Assured switch-off distance s
ar
- in x/z direction
- in y direction
-
-
-
-
40
60