![EUCHNER CES-AP-C01- Series Скачать руководство пользователя страница 9](http://html.mh-extra.com/html/euchner/ces-ap-c01-series/ces-ap-c01-series_operating-instructions-manual_2434829009.webp)
9
112663-05-03/15 (translation of the original operating instructions)
Operating Instructions
Non-Contact Safety Switch CES-AP-C01-…
EN
8. Mounting
CAUTION
Safety switches must not be bypassed (bridging of contacts), turned away, removed or otherwise
rendered ineffective.
Ì
Observe EN ISO 14119:2013, section 7, for information about reducing the possibilities for by-
passing an interlocking device.
NOTICE
Risk of damage to equipment and malfunctions as a result of incorrect installation.
Ì
Safety switches and actuators must not be used as an end stop.
Ì
Observe EN ISO 14119:2013, sections 5.2 and 5.3, for information about fastening the safety
switch and the actuator.
Ì
From the assured switch-off distance S
ar
, the safety outputs are safely shut down.
Ì
When mounting several safety switches, observe the stipulated minimum distance to avoid mutual
interference.
.
min . 40 mm
Ì
If the actuator is installed flush, the switching distance changes as a function of the installation
depth and the safety guard material.
Operating
distance
Actuator
Operating
distance
Actuator
Flush mounting
Surface mounting
Note the following points:
Ì
Actuator and safety switch must be easily accessible for inspection and replacement.
Ì
Actuator and safety switch must be fitted so that
-the front faces are at the minimum switch-on distance 0.8 x S
ao
or closer when the safety guard is closed. To avoid
entering the area of possible side lobes, a minimum distance is to be maintained in case of a side approach direction.
See chapter
6. Technical data,
section
Typical operating distance
of the respective actuator.
-when the safety guard is open up to the distance S
ar
(assured switch-off distance), a hazard is excluded.
-the actuator is positively mounted on the safety guard, e.g. by using the safety screws included.
-they cannot be removed or tampered with using simple means.
Ì
Pay attention to the maximum tightening torque for the read head or safety switch and actuator mountings of 1 Nm.