Operating Instructions
Non-Contact Safety Switch CES-AP-C01-…
18
(translation of the original operating instructions) 112663-05-03/15
5. System status table
Operating mode
Actuator/door po
-
sition
Safety outputs OA and OB
LED indicator,
output
State
ST
ATE (gr
een)
DIA (r
ed)
Normal operation
closed
on
Normal operation, door closed
closed
on
flashes
quickly
2 Hz
Normal operation, door closed, actuator in limit range
¨
re-adjust door
open
off
1 x
Normal operation, door open, no actuator taught
Teach-in operation
(unicode only)
open
off
3 x
Door open, unit is ready for teach-in for another actuator (only short time after power-up)
closed
off
1 Hz
Teach-in operation
X
off
Positive acknowledgment after completion of teach-in operation
Fault display
closed
off
3 x
Defective actuator (e.g. fault in code or code not readable)
X
off
4 x
Output error (e.g. short circuits, loss of switching ability)
X
off
5 x
Internal fault (e.g. component faulty, data error)
Key to symbols
LED not illuminated
LED illuminated
10 Hz (8 s)
LED flashes for 8 seconds at 10 Hz
3 x
LED flashes three times, and this is then repeated
X
Any state
After the cause has been remedied, faults can generally be reset by opening and closing the safety guard. If the fault is
still displayed afterward, briefly interrupt the power supply. Please contact the manufacturer if the fault could not be reset
after restarting.
Important!
If you do not find the displayed device status in the System status table, this indicates an internal
device fault. In this case, you should contact the manufacturer.