![EUCHNER CES-AP-C01- Series Скачать руководство пользователя страница 12](http://html.mh-extra.com/html/euchner/ces-ap-c01-series/ces-ap-c01-series_operating-instructions-manual_2434829012.webp)
Operating Instructions
Non-Contact Safety Switch CES-AP-C01-…
12
(translation of the original operating instructions) 112663-05-03/15
9.5. Connector assignment for safety switch CES-AP-C01
View on the connection side of the safety switch
Plug connector
8
2
7
6
1
3
4
5
UB
0V
n.c.
n.c.
OA
OB
DIA
RST
1
3
2
4
5
UB
0V
OA
OB
DIA
1
3
2
4
5
UB
0V
OA
OB
n.c.
8
3
5
7
4
2
1
6
3
5
4
1
2
8
2
7
6
1
3
4
5
UB
0V
n.c.
n.c.
OA
OB
DIA
RST
1
3
2
4
5
UB
0V
OA
OB
DIA
1
3
2
4
5
UB
0V
OA
OB
n.c.
8-pin
5-pin
8
2
7
6
1
3
4
5
UB
0V
n.c.
n.c.
OA
OB
DIA
RST
1
3
2
4
5
UB
0V
OA
OB
DIA
1
3
2
4
5
UB
0V
OA
OB
n.c.
8-pin
5-pin
5-pin;
pin 5 not used
Figure 1:
Connector assignment for safety switch CES-AP-C01
Plug connector pin
Designation
Description
Wire color as per
DIN 47100
8-pin
5-pin
5-pin, pin 5 not used
1
-
-
n.c.
Not used
White
2
1
1
UB
Power supply, DC 24 V
Brown
3
2
2
OA
Safety output, channel 1
Green
4
4
4
OB
Safety output, channel 2
Yellow
5
5
-
DIA
Monitoring output
Gray
6
-
-
n.c.
Not used
Pink
7
3
3
0V
Ground, DC 0 V
Blue
8
-
-
RST
Reset input for hardware reset
Red