16
6. Technical Specifications
The specifications apply when the power supply series are powered on for at least 30 minutes under regulated
temperature.
Model
eTM-K1560SP
eTM-K3030SP
eTM-K6015SP
eTM-K3020SP
eTM-K6010SP
Range
15V/60A
30V/30A
60V/15A
30V/20A
60V/10A
Rated output (0
℃
~40
℃
)
Voltage
0~15V
0~30V
0~60V
0~30V
0~60V
Current
0~60A
0~30A
0~15A
0~20A
0~10A
OVP
0.1~18V
0.1~34V
0.1~64V
0.1~34V
0.1~64V
OCP
0.1~62 A
0.1~34A
0.1~17A
0.1~24A
0.1~12A
Constant Voltage Operation (CV)
Line regulation
≤0.01%+4mV
Load regulation
≤0.1%+5mV
Recovery time
≤1.5ms (50% load change)
Ripple & Noise
2mVrms, 30mVpp
Temperature co-efficient
≤300ppm/
℃
Constant Current Operation (CC)
Line regulation
≤0.2%+3mA
Load regulation
≤0
.2%+5mA
Ripple & Noise
≤10mArms
Display
Voltmeter
5 digits display
Ammeter
5 digits display
Setting resolution
1mV/1mA
Reading resolution
1mV/1mA
Setting
accuracy
Voltage
±(0.03% of r 10mV) (25±5
℃
)
Current
±(0.3% of r 10mA) (25±5
℃
)
Reading
accuracy
Voltage
±(0.02% of r5mV) (25±5
℃
)
Current
±(0.05% of r10mA) (25±5
℃
)
Protection
Over load, over voltage, over current, over temperature and reverse polarity protections
Programming interface
RS-232, support SCPI commands
Memory
100 sets
Insulation
Between terminals and chassis/other terminals: ≤60VDC
Power source
AC220V±10%, 50/60Hz
AC110/220V±10%, 50/60Hz
Accessory
Operation manual x1, Power cord x1, Software CD x1, RS-232 cable x1
Dimension(W*H*D)
215×89×412mm
215×89×352mm