7
Setting method 1: Press
[numeric buttons 0-9] [Enter]
to complete delay time setting.
Setting method 2: Press buttons
[
]
or
[
]
to move the cursor left or right. Rotate the rotary knob left or right to
increase or decrease the digit on cursor.
For example: Set the delay time to 99999s.
Press
[Menu] [9] [9] [9] [9] [9] [Enter]
.
Note:
The Delay setting is effective only under the Auto running operation. Delay setting will be saved to the
memory address simultaneously.
3.8 Function Setup
Press
[Shift] [4]
buttons to
proceed to “
Utility
”
function setting, then press
[Menu]
to select the options under the
this function.
3.8.1 Voltage Step Setting
Press
[Menu]
button
until “Utility V Step” is shown on the LCD.
Set the maximum value of Step to be the
maximum value of the voltage range.
Setting method 1: Press
[numeric buttons 0-9] [Decimal Point] [Enter]
to set step voltage.
Setting method 2: Press buttons
[
]
or
[
]
to move the cursor left or right. Rotate the rotary knob left or right to
increase or decrease the digit on cursor.
For example: Set the step voltage to 10.000V.
Press
[1] [0] [.] [0] [0] [0] [Enter]
.
3.8.2 Current Step Setting
Press
[Menu]
button
until “Utility I Step” is shown on the LCD.
Set the maximum value of Step to be the
maximum value of the current range.
Setting method 1: Press
[numeric buttons 0-9] [Decimal Point] [Enter]
to set step current.
Setting method 2: Press buttons
[
]
or
[
]
to move the cursor left or right. Rotate the rotary knob left or right to
increase or decrease the digit on cursor.
For example: Set the step current to 0.500A.
Press
[0] [.] [5] [0] [0] [Enter]
.