Error codes internal generator
Code
Description
Cause
Solution
F/6
Mains voltage zero
crossing is not
detected.
Connection error.
Check the connection.
F/J
Mains voltage is
too high.
Connection error.
Check the connection..
F/3
Generator
temperature sensor
is in short-circuit.
Internal error.
Reset the appliance (disconnect the
appliance from the power supply for
a while). If this does not solve the
problem, please contact the service
department.
F/4
Generator
temperature sensor
is defect / is in
open-circuit.
Internal error.
Reset the appliance (disconnect the
appliance from the power supply for
a while). If this does not solve the
problem, please contact the service
department.
F/9
The cooling fan
doesn’t work
properly.
The fan is blocked.
Reset the appliance (disconnect the
appliance from the power supply for
a while). If this does not solve the
problem, please contact the service
department.
Zone related error codes: please contact the service department.
Code
Description
Cause
Solution
F/8
Temperature of the
zone cannot be
measured.
Coil NTC defective,
generator defective.
1. Replace the induction coil.
2. Replace the induction generator.
F/1
Heater NTC is in
short-circuit.
Sensor defect.
1. Replace the induction coil.
2. Replace the induction generator.
F/2
Heater NTC is in
open-circuit.
Sensor defect, not
connected.
1. Replace the induction coil.
2. Replace the induction generator.
F/7
The induction coil
does not measure
a temperature
change.
The internal connection
of the induction coil has
been reversed.
1. Check induction coil with
temperature sensor connection.
2. Replace the induction coil.
3. Replace the induction generator.