SETUP
DOC_DEV_Router setup guide_A
page 67
19.3.2
Raw server gateway
That gateway can be used if a serial slave device has to answer requests coming from devices located on the
IP network and acting like a master (also called TCP client).
To configure the gateway :
•
In the menu, choose
Setup > IP-RS gateways > Transparent > Raw server COMx
•
Tick the
Enable
checkbox.
•
Configure the following parameters.
Bitrate, Parity, Data, stop bits
Allow to set the bitrate and the format of the asynchronous serial link.
Receive buffer size
Set up the maximum length of an asynchronous string the gateway will store before transmitting it to the IP
network.
RS end frame timeout
Set up the delay the gateway will wait before declaring complete a string received from the asynchronous
device.
Once declared complete, the gateway will transmit the string to the IP network.
TCP idle Timeout
Set the time the gateway will wait before disconnecting the TCP link if no characters are detected.
TCP port
Set the port number the gateway has to use.
Warning : If two gateways of the same type are active on the two serial ports, they can not use the same TCP
port number.