background image

                                                                                            KL8-3 

 

the power supply. and the LCD display 

---

”。

 

2

 please note that it shows "on" or  "off" on the  LCD, "on"  means pre-heating is   

turn on, when the    time of pre-heating is the same as currently time, the heater 
will start working. "off" means the heater can't start-up anytime

 

3

 Circulation PUMP and HEATER are not working while all setting time

 

 

  (6) Pre-heating

 

When the time of real time and pre-heating time is consistent

  meanwhile

  there is water in the bathtub 

and  the  pre-heating  button  is

on

”,

  the  system  will  start  the  pre-heating  and  circulation  pump  and 

auto-constant temperature system will work at the same time

  Then LCD will show count down time 

the 

two middle spot will not flash any longer

  and corresponding working status

    In the pre-heating process

 

till cont down time finished

  the pre-heating will be turned off automatically by system or by pressing the

key intentionally

 

***

 

Notice *** 

1

 

When setting temperature is lower or equal water temperature

Even the 

Pre-heating  is  working  but  the  circulation  PUMP  and  HEATER  are  not 
working

 

2

 

When  the HEATER is 

I

frame

The power of circulation PUMP must 

reach 750W

 

3

 

Answer for condition of 

2

”,

and the HEATER is not working

Please 

short the line of water press switch

 

 

(7)circulation-cleaning: 

When  the  time  of  real  time  and  pre-heating  time  is  consistent,  meanwhile,  there  is  water  in  the 

bathtub and the circulation-cleaning button is

on

  the system will start the circulation-cleaning

  and the 

circulation pump and ozone(If it is on) will work at the same time

  Then LCD will show count down time

  In 

the  circulation-cleaning  process

  till  cont  down  time  finished  the  circulation-cleaning  will  be  turned  off 

automatically by system or by pressing   

  key intentionally

 

 

(8) Operation to Power ON/ OFF 

Pressing the key 

  will enter from ON to 

Waitting Mode

  or 

Waitting Mode

  to ON

  At 

the same time

  the LCD will show whether the power is on or off

 

OFF

               

OFF

 

Fig

9

WAITTING MODE                                                    Fig

10

  ON 

 

(9) Operation to Temperature setting 

In the status of 

Power-on

  and 

HEATER

  is working 

The temperature setting can operate

 

only key 

are available

  It will add 1

  when pressing 

  and the temperature could be 

Содержание KL8-3

Страница 1: ...y Lock Surf Water pump 1 ON OFF Radio searching Shift of Circulation or Preheat setting Surf Water pump 1 ON OFF Long Circulation Cleaning ON OFF Setting Of circulation Cleaning Surf Water pump 3 ON O...

Страница 2: ...t will show E1 if the sensor is open short circuit When part of radio frequency showed it indicates that the status of the system is Waitting Mode so as well as the pre heat and circulation cleaning F...

Страница 3: ...6 Fig 5 Circulation cleaning off Fig 6 Circulation cleaning on Circulation cleaning setting must be in the Waitting Mode status and the LCD display 1 Close of Circulation cleaning setting 2 Setting St...

Страница 4: ...4 When everything is setting well Press the system will quit the Circulation cleaning setting status with save Notice 1 all setting of Circulation cleaning must be in Waitting mode status 2 Circulatio...

Страница 5: ...this time will not flash It will add 5 minutes by pressing each time And add 1 hour by pressing each time please note that the maximum of continual time is 19 hours and 55 minutes When you set up wel...

Страница 6: ...re heating is working but the circulation PUMP and HEATER are not working 2 When the HEATER is I frame The power of circulation PUMP must reach 750W 3 Answer for condition of 2 and the HEATER is not w...

Страница 7: ...essing the key will take out the memorized radio frequency Pressing the key continually will take out the memorized radio frequency from channels will be saved at present channel by pressing this key...

Страница 8: ...f the heater 15 Operation to blower there is a key C F controlling the on off of blower 16 Fahrenheit Celsiur temperature shift In the status of Waitting Mode pressing the key C F can change the mode...