background image

                                                                                            KL8-3 

 

added  continually    till  45

  when  pressing  the 

without  stop

At  this  time 

  when  pressing 

  angin

and the temperature could return 15

 

The range of adjustment is 15~45

 

 

 

(10)Operation Radio & CD: 

OFF

 

Fig

11

  Radio frequency is 105.2 MHZ

Save the present frequency to channel 3 (Save channel)   

or Exchange the frequency form channel 3 to the present (Searching channel) 

)

Key 

  is the ON/OFF key for radio and CD

and it is only available in the status of power 

on. The first pressing is turning on the radio

the second pressing will turn off the radio and turn on the CD at 

the same time

and the third

will turn off the radio and CD simultaneous

 

Ⅱ)、

LCD will show present frequency and volume of the radio after turning on the radio

 

Ⅲ)、

In the working of radio

  The volumle of the present radio frequency can be changed by pressing 

&

 

 

Ⅳ)、

Pressing the key 

  will take out    the memorized radio frequency

Pressing the key

    continually will take out the memorized radio frequency from channels will be saved at present 

channel by pressing this key continually

If none of the channel

  LCD will display 

---

 

Ⅴ)、

Press the key

 

  could memorize the present    radio frequency

  Pressing the key

 

    continually will memorize the present radio frequency in different channel

  The channel of 

max is 10

Name of channel is 0-9

 

Ⅵ)、

The volume can be changed by pressing key 

+

&

-

”。

 

 

(11)Operation to Pump : 

KEY of    “Pump1/2/3”    are control surf pump1/2/3

 

 

(12) Operation to Long Circulation

 

Press the key 

  to turn on/off the Long Circulation

  After the startup of Long Circulation

 

The surf PUMPs and BLOWER will work once in 30 minutes

They will work 30 seconds

  The OZONE will 

work once in 30 minutes

They will work 15 minutes

 

When one of the surf PUMPS or BLOWER is working

The ozone will be turned off automatically

 

 

(13) Operation to Bottom lamp

 

 

controlling the ON/OFF of the lamp in the bottom of the bathtub

 

Содержание KL8-3

Страница 1: ...y Lock Surf Water pump 1 ON OFF Radio searching Shift of Circulation or Preheat setting Surf Water pump 1 ON OFF Long Circulation Cleaning ON OFF Setting Of circulation Cleaning Surf Water pump 3 ON O...

Страница 2: ...t will show E1 if the sensor is open short circuit When part of radio frequency showed it indicates that the status of the system is Waitting Mode so as well as the pre heat and circulation cleaning F...

Страница 3: ...6 Fig 5 Circulation cleaning off Fig 6 Circulation cleaning on Circulation cleaning setting must be in the Waitting Mode status and the LCD display 1 Close of Circulation cleaning setting 2 Setting St...

Страница 4: ...4 When everything is setting well Press the system will quit the Circulation cleaning setting status with save Notice 1 all setting of Circulation cleaning must be in Waitting mode status 2 Circulatio...

Страница 5: ...this time will not flash It will add 5 minutes by pressing each time And add 1 hour by pressing each time please note that the maximum of continual time is 19 hours and 55 minutes When you set up wel...

Страница 6: ...re heating is working but the circulation PUMP and HEATER are not working 2 When the HEATER is I frame The power of circulation PUMP must reach 750W 3 Answer for condition of 2 and the HEATER is not w...

Страница 7: ...essing the key will take out the memorized radio frequency Pressing the key continually will take out the memorized radio frequency from channels will be saved at present channel by pressing this key...

Страница 8: ...f the heater 15 Operation to blower there is a key C F controlling the on off of blower 16 Fahrenheit Celsiur temperature shift In the status of Waitting Mode pressing the key C F can change the mode...

Отзывы: