A6:    OFF: When the temperature appears abnormal, all high-voltage loads will stop working. 
          ON: All high-voltage loads are not affected by temperature sensor control. At this time, it 

can choose not to connect with the heater.   

A7:    OFF: With a flowing induction sensor, when it is detected to be without flowing, the heater 

doesn’t work. 

          ON: Without flowing induction sensor. 
A8

OFF: With voltage detecting of inputting and the protection of overvoltage and undervoltage is 

working. 

          ON: Without the protection of overvoltage and undervoltage. 
 
B1

OFF: Normal mode.   

          ON: Test mode. 
B2

OFF: With current limit control, the maximum working current is 16A. 

          ON: Without current limit control 
B3

OFF: Without moisturizing function and at this time there is with 12 V power output of LED 

          ON: With moisturizing function 
B4

OFF: Only with 1 surfing pump.   

          ON: With 2 surfing pump. 

***note*** 

1. The setting of all the jumpers is effective only when it is repowered on. And the spacing interval 

for re-power on is more than 60 seconds. 

2.  All  the  jumpers  have  been  set  in  the  factory.  The  user  had  better  not  change  the  product 

setting.   

3. When any surfing pump is turned on, the heater stops working. 

 

.The operating instructions of high-voltage load 

).The operation of surfing pump 

Press “

” to control the pump ON/OFF, and the surfing pump will automatically turn off 

after 15 minutes. 

 

).The operation of the Blower 

 

” is to control the blower for turning on/off. The blower will automatically turn off 

after 15 minutes. 
 

The operation of the Light 

  “

” is to control the light for turning on /off. The light will automatically turn off after 

120 minutes. 

***note*** 

Содержание KL6600

Страница 1: ...er Mode 2 Plug and play mode is to get easy operation and easy installation 3 24 hours clock display and setup of circulation cleaning 4 Max 3KW of the heater water temperature display and the setting...

Страница 2: ...over voltage if it is beyond 260VAC then LED shows In these two kinds of situation the system will not go into normal operation Under this circumstance that the input voltage is normal the system woul...

Страница 3: ...ton and hold until it appears some icons or enters to a certain status 4 Click pressing means to click the button and let go right now within a second Working Mode 1 When A1 ON there is without neithe...

Страница 4: ...ice filtering antivirus cycle every day But it is only able to set the start time for the first filtering antivirus cycle And the second filtering cycle is automatically added it will starts after 12...

Страница 5: ...7 7 If the current water temperature shows 98 but the real water temperature is 100 At the moment as long as to adjust the fine tuning number for 2 the showing temperature will turn into 100 1 2 3 4...

Страница 6: ...sturizing function and at this time there is with 12 V power output of LED ON With moisturizing function B4 OFF Only with 1 surfing pump ON With 2 surfing pump note 1 The setting of all the jumpers is...

Страница 7: ...r temperature is reaching 46 7 8 or above all the heaters and circulating pumps stop working The operation of auto moisturizing B3 ON 1 When the water level pin detects that there is no water LCD show...

Страница 8: ...Installation structure KEY_DIS SENSOR A OZONE 220V 12VAC 1A 250V HT48R06A 1 LIGHT HT46R23 WCS2705 WCS2705 ON 1 2 3 4 5 6 7 8 ACN P1 P1L BLOWER ACN AUX ACN ACL ACN ACN ACN HT1 HT2 KL6600 ACN P1L Fig 8...

Страница 9: ...ure that the water flow inside the heater is not enough 1 Check whether filter is blocking or is just replaced 2 Check whether the metering valves and circulating pump are normal or not 3 If the above...

Страница 10: ...240V Compression strength 1250V 1 minute Not being punctured Insulation resistance 200M Waterproof level IPX5 Electric shock preventing 1 class 2 Maximum output load index Heater 4KW 220 240VAC Surfi...

Отзывы: