ETHINK KL6600 Скачать руководство пользователя страница 4

                                                                                      KL6600 

www.ethink-spa.com

                                                                  4 

setting temperature.

 And it will not start to heat at the second filter cycle. 

2.5 The 4th time to press “

”, the system enters to “Filter Mode”, the LED shows “

”.

 

***Note*** 

When  A2=ON,  there  is  without  “Economy  Mode”  and  it  will  auto  ignore  the  fourth  step  when 

operation. 

).Clock setting 

At clock setting status, (show as Fig. 4), press “

” to set the hour (down button), the 

adjusting range is from “0 to 23”.And to press the “

” to set the minute (up button), the 

adjusting range is from “0 to 59” 
 

                   

 

Fig. 3: Current time 12:34                                  Fig.4: Start time of filtration at 3:00. 

).Pre-settings filtering antivirus cycle (Valid of A1=off)

 

1. It has twice filtering antivirus cycle every day. But it is only able to set the start time for the first 

filtering antivirus cycle. And the second filtering cycle is automatically added, it will starts after 
12  hours  later.  (For  example,  it  starts  at  14:00  and  the  start  time  of  the  second  filtering  is  at 
2:00) 

2. When A3 = ON, the time for filtering antivirus is fixed. It starts to work at 14:00 every day, and it 
lasts for 3 hours. And the start time of the second filtering is at 2:00. 

3. When A3= OFF, at setup status of “start time of filtering cycle” (Fig.4).Press “

” to change 

starting time, and both hour and minute are 00. 

4.  At  setup  status of  “continuous  working time  of  filtering  cycle”,  press  “

” to  change the 

time, the settings are 1-11 hours, and the default time is 3 hours (Fig. 5). 

             

 

Fig. 5: filtering lasts for 3 hours                        Fig. 6: Temperature Adjust 

Содержание KL6600

Страница 1: ...er Mode 2 Plug and play mode is to get easy operation and easy installation 3 24 hours clock display and setup of circulation cleaning 4 Max 3KW of the heater water temperature display and the setting...

Страница 2: ...over voltage if it is beyond 260VAC then LED shows In these two kinds of situation the system will not go into normal operation Under this circumstance that the input voltage is normal the system woul...

Страница 3: ...ton and hold until it appears some icons or enters to a certain status 4 Click pressing means to click the button and let go right now within a second Working Mode 1 When A1 ON there is without neithe...

Страница 4: ...ice filtering antivirus cycle every day But it is only able to set the start time for the first filtering antivirus cycle And the second filtering cycle is automatically added it will starts after 12...

Страница 5: ...7 7 If the current water temperature shows 98 but the real water temperature is 100 At the moment as long as to adjust the fine tuning number for 2 the showing temperature will turn into 100 1 2 3 4...

Страница 6: ...sturizing function and at this time there is with 12 V power output of LED ON With moisturizing function B4 OFF Only with 1 surfing pump ON With 2 surfing pump note 1 The setting of all the jumpers is...

Страница 7: ...r temperature is reaching 46 7 8 or above all the heaters and circulating pumps stop working The operation of auto moisturizing B3 ON 1 When the water level pin detects that there is no water LCD show...

Страница 8: ...Installation structure KEY_DIS SENSOR A OZONE 220V 12VAC 1A 250V HT48R06A 1 LIGHT HT46R23 WCS2705 WCS2705 ON 1 2 3 4 5 6 7 8 ACN P1 P1L BLOWER ACN AUX ACN ACL ACN ACN ACN HT1 HT2 KL6600 ACN P1L Fig 8...

Страница 9: ...ure that the water flow inside the heater is not enough 1 Check whether filter is blocking or is just replaced 2 Check whether the metering valves and circulating pump are normal or not 3 If the above...

Страница 10: ...240V Compression strength 1250V 1 minute Not being punctured Insulation resistance 200M Waterproof level IPX5 Electric shock preventing 1 class 2 Maximum output load index Heater 4KW 220 240VAC Surfi...