Hardened Web-Smart PoE Ethernet Switch
2 User’s Manual
LED State
Indication
Steady
A valid network connection established.
Link/ACT
Flashing
Transmitting or receiving data.
ACT stands for ACTIVITY.
Steady
Power Device (PD) is connected.
PoE
Off
Power Device (PD) is disconnected.
Power Input Assignment
Power3 48VDC
DC
Jack
+
48VDC
Power2
-
Power Ground
+
48VDC
Power1
-
Power Ground
Earth Ground
Terminal
Block
Relay Output Rating
0.1A @ 24VDC
Relay Alarm Assignment
FAULT
*Warning signal disable for following:
The relay contact closes if Power1 and Power2
are both failed but Power3 on.
The relay contact closes if Power3 is failed but
Power1 and Power2 are both on.
DC Terminal Block Power Inputs: There are two pairs of power inputs can be
used to power up this switch. Redundant power supplies function is
supported.
The 10/100Base-TX and 100Base-FX Connectors
The 10/100Base-TX Connections
The following lists the pinouts of
10/100Base-TX ports.
Pin Regular Ports
Uplink port
1
Input Receive Data +
Output Transmit Data +
2
Input Receive Data -
Output Transmit Data -
3
Output Transmit Data + Input Receive Data +
4 NC
NC
5 NC
NC
6
Output Transmit Data - Input Receive Data -
7 NC
NC
8 NC
NC