background image

Q u i c k   G u i d e :

Unison AV/Serial Interface v1.1.0 Quick Guide

Unison AV/Serial Interface v1.1.0 Quick Guide

Page 2 of 10

Electronic Theatre Controls, Inc.

• Faders: These represent the station's virtual faders. Faders can be set to any level from zero 

to full on (100%). Each virtual fader also has a virtual LED, which is also a read-only 
property.

• Rates: The station also utilizes fade rates to facilitate smooth and level transitions given the 

limited bandwidth of RS232. There is a configurable rate that corresponds with each fader 
of the station. When a new fader level is given, the fader is moved at the set rate to the 
new level. Rate is set in a unit of seconds.

• Levels: A Level is a configurable feedback mechanism for up to 16 zones that report the 

actual level of the configured zone to the serially connected device.

With Emphasis [Serial Button Protocol]

The Unison AV/Serial Interface has a second mode of 
operation that interfaces with an Emphasis 
Facepanel or ECS LPC via RS232 and Serial Button 
Protocol. This mode of operation is set either by 
installing the jumper on J2 to the “B” side (the 
preferred method), or by sending a specified serial 
command to the device. In this mode, commands that 
set the LED state for buttons 1 thru 16 result in 
activation of macros 101 thru 116 on the serially 
connected Emphasis. Please see the Emphasis User 
Manual (v1.4.0 or later) for more details about the 
Emphasis Serial Button Protocol. 

The Unison AV/Serial Interface station protocol as 
defined in this document is still accepted from host to 
station to allow any reconfiguration of the station. The 
Unison Light Manager configuration must be 
configured with the default AV/Serial Interface station 
type (ST3300). Enabling Emphasis mode forces the 
station to be the default type if it was previously changed; alternate station types are not 
allowed. If the Unison configuration uses any other station, the physical station will not 
bind/connect to the system.

Emphasis mode Light Manager configuration example:

The 16 buttons of the AV/Serial Interface station are configured as zone bump toggle for 
zones 1 - 16. When zone one’s level changes from 0% to 100%, the AV/Serial Interface 
station sends a command to execute macro number 101 of the serially connected 
Emphasis system. Nothing is sent when zone one is returned to 0%.

PCB Top Side

Unison Link 
Power (ULP)

J2 jumper for 
Emphasis Serial 
Button Protocol mode

Unison Aux 
Power (+24Vdc)

Содержание Unison AV/Serial Interface v1.1.0

Страница 1: ...late the virtual buttons faders and rates with serial commands Presets macros or other Unison station events may be activated or deactivated using this station Feedback information is passed back in t...

Страница 2: ...ethod or by sending a specified serial command to the device In this mode commands that set the LED state for buttons 1 thru 16 result in activation of macros 101 thru 116 on the serially connected Em...

Страница 3: ...nd the PC Interface station have different electronics and are not interchangeable In addition the AV Serial interface station must include neuron code v1 4 or later to function properly with Light Ma...

Страница 4: ...ta RX pin 5 Common Use a communications terminal application such as Hyper Terminal to interface with the station Com port settings are 9600 baud 8 bits no parity 1 stop bit and Xon Xoff flow control...

Страница 5: ...nd F Fader U Update An automatic system response initiated by a status change of an item on the station such as a button s LED turning on L Level M Memory R Rate S Status T Type V Version Object Get C...

Страница 6: ...nstalled bound Bit Description 0 Station reset occurred 1 Station wink occurred 2 A command error occurred 3 UART error occurred 4 5 Unison install status 00 unistalled 01 installed 10 bound 6 15 Unus...

Страница 7: ...off set levels to 0 and clear bindings Notes Configuration switches are stored in EEROM and are retained during a power loss When packet mode is enabled commands are prefixed with a one byte preamble...

Страница 8: ...the button and fader mapping to a physical station faders are numbered right to left and buttons 1 10 are on the right side of the faders and 11 12 are on the left The AV Serial Interface station s b...

Страница 9: ...matically if there is only single station of that type in the Unison configuration Additional Notes Comments Single Byte Commands The Cancel command flushes command buffer and cancels Xoff command SF0...

Страница 10: ...type the preamble character by holding the Alt key while typing the 4 digit number listed while using a terminal emulator such as Hyper Terminal You will see the display character if you have local ec...