background image

E T C

®

  Q u i c k   G u i d e

Unison

®

 AV/Serial Interface v1.1.0 (LM v1.9.1)

Unison AV/Serial Interface v1.1.0 Quick Guide

Page 1 of 10

Electronic Theatre Controls, Inc.

Americas

 

„

 3031 Pleasant View Road, P.O. Box 620979, Middleton, Wisconsin 53562-0979 USA 

„

 Tel: +608 831 4116 

„

 800 688 4116 

„

 Fax: +608 836 1736 

„

 800 555 8912

Europe

 

„

 Unit 5, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK 

„

 Tel: +44 (0)20 8896 1000 

„

 Fax: +44 (0)20 8896 2000

Asia

 

„

 Room 605-606, Tower III Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong 

„

 Tel: +852 2799 1220 

„

 Fax: +852 2799 9325

Web:

 

www.etcconnect.com

 

„

 

Email:

 (US) 

[email protected]

 

„

 (UK) 

[email protected]

 

„

 (Asia) 

[email protected]

Service: 

(US) 

[email protected]

 

„

 

(UK) 

[email protected]

 

„

 

(Asia) 

[email protected]

 

„

 Comments about this document: 

[email protected]

7081M1301-1.1.0

 

„

 Rev A 

„

 Released 11/2004 

„

 Copyright © 2004 ETC. All Rights Reserved. 

„

 Product information and specifications subject to change.

Overview

This quick guide is intended for use by ETC trained technicians and technicians 
programming devices that will communicate with Unison via a serial interface. It assumes 
an intermediate level of familiarity and experience with the equipment involved.

With Unison

The Unison AV/Serial Interface station provides a method for 
PCs or any other type of device capable of RS232 serial 
communication to control and interact with a Unison control 
system. The AV/Serial Interface acts as virtual station with 
similar functionality to existing station types except you 
manipulate the virtual buttons, faders and rates with serial 
commands. Presets, macros or other Unison station events 
may be activated or deactivated using this station. Feedback 
information is passed back in the form of responses and by 
polling the status of the virtual buttons and faders (similar to 
the visual feedback LEDs on a standard wall station).

This station, with neuron code v1.1.0 and later, also features 
a short configuration independent communications protocol 
for ease of implementation. Due to the simplicity of the 
station, more than one station may be used in a system. 
Contact ETC Project Management for assistance.

Light Manager™ Software

The functionality of the AV/Serial Interface station, in a Unison system is easily configured 
by adding the new AV/Serial Interface station into an existing Light Manager configuration. 
The default station type is a 16 button, 16 fader, and 16 zone levels (ST3300). By default, 
the station has no assignments. 

The Unison AV/Serial Interface station protocol (the serial communication as defined in 
this document) defines the serial interaction with the station itself. It supports manipulation 
of four virtual objects to control the functions configured in Light Manager:

• Buttons: These represent the station's virtual buttons. A button's state can be maintained on 

as though someone were holding it down, or simply be off. There is also a command to 
execute a “press”, which simulates a press and release of a button (the most common 
use). Each virtual button on the station has a corresponding virtual LED to indicate 
function state. These LEDs are controlled by the Unison processor and are read only.

2.80"

4.50"

FRONT VIEW

AV/Serial Interface

Computer

Level

Fader

Button

Содержание Unison AV/Serial Interface v1.1.0

Страница 1: ...late the virtual buttons faders and rates with serial commands Presets macros or other Unison station events may be activated or deactivated using this station Feedback information is passed back in t...

Страница 2: ...ethod or by sending a specified serial command to the device In this mode commands that set the LED state for buttons 1 thru 16 result in activation of macros 101 thru 116 on the serially connected Em...

Страница 3: ...nd the PC Interface station have different electronics and are not interchangeable In addition the AV Serial interface station must include neuron code v1 4 or later to function properly with Light Ma...

Страница 4: ...ta RX pin 5 Common Use a communications terminal application such as Hyper Terminal to interface with the station Com port settings are 9600 baud 8 bits no parity 1 stop bit and Xon Xoff flow control...

Страница 5: ...nd F Fader U Update An automatic system response initiated by a status change of an item on the station such as a button s LED turning on L Level M Memory R Rate S Status T Type V Version Object Get C...

Страница 6: ...nstalled bound Bit Description 0 Station reset occurred 1 Station wink occurred 2 A command error occurred 3 UART error occurred 4 5 Unison install status 00 unistalled 01 installed 10 bound 6 15 Unus...

Страница 7: ...off set levels to 0 and clear bindings Notes Configuration switches are stored in EEROM and are retained during a power loss When packet mode is enabled commands are prefixed with a one byte preamble...

Страница 8: ...the button and fader mapping to a physical station faders are numbered right to left and buttons 1 10 are on the right side of the faders and 11 12 are on the left The AV Serial Interface station s b...

Страница 9: ...matically if there is only single station of that type in the Unison configuration Additional Notes Comments Single Byte Commands The Cancel command flushes command buffer and cancels Xoff command SF0...

Страница 10: ...type the preamble character by holding the Alt key while typing the 4 digit number listed while using a terminal emulator such as Hyper Terminal You will see the display character if you have local ec...

Отзывы: