ETC

Truss Mounting Clamps

Truss mounting clamps are available from ETC, sold separately.

Part Number Description

PSF1131

Mega-Coupler™ Clamp 1.9" Pipe/2.0" Truss, Black

PSF1132

Mega-Coupler Clamp 1.9" Pipe/2.0" Truss, White

PSF1133

Mega-Claw™ Clamp 1.9" Pipe/2.0" Truss, Black

PSF1134

Mega-Claw Clamp 1.9" Pipe/2.0" Truss, White

PSF1135

Trigger Clamp™ 1.9" Pipe/2.0" Truss Tube, Black

PSF1136

Trigger Clamp 1.9" Pipe/2.0" Truss Tube, White

Spacing Requirements

For full pan and tilt operation, install the Relevé Spot with a minimum of 27.0 in (68.6 cm) between
centers. The luminaire features Whisper Home technology, which provides instant pan and tilt
homing at power on with minimal movement. You can install the luminaires closer together if you
restrict the pan and/or tilt movement using the features provided for pan and tilt in the Options
menu.

Note:

Add additional spacing between luminaires when using accessories such as a top

hat. Refer to the accessory datasheet for dimensions.

Rigging

WARNING:

RISK OF INJURY! Check each clamp mounting rail and truss clamp

for proper and secure installation before hanging the luminaire.

AVERTISSEMENT :

DANGER DE BLESSURE ! Avant d’accrocher le luminaire,

vérifiez chaque crochet et chaque porteuse pour une installation correcte et en
sécurité.

Relevé Spot can be yoked in any mounting position using the provided hanging points. The luminaire
can also be installed on the floor or a suitable level, horizontal, and flat surface. Rubber feet are
provided on the base of the enclosure.

Содержание Releve Spot

Страница 1: ...exposed to extreme cold or heat outside of the operational range see Environment on the next page moisture or dust Do not project the light beam onto combustible surfaces or materials The minimum dis...

Страница 2: ...bjects IPx0 indicates no protection against liquid contact and ingress of liquid objects Attach Clamp Mounting Rails CAUTION Risk of Personal Injury Overhead mounting requires extensive experience inc...

Страница 3: ...he next page or other compatible hardware for installation The clamp mounting rails feature a safe latching system for secure fit to the hanging points on the enclosure 1 Install the truss clamps not...

Страница 4: ...n and tilt homing at power on with minimal movement You can install the luminaires closer together if you restrict the pan and or tilt movement using the features provided for pan and tilt in the Opti...

Страница 5: ...e Belden 9729 or equivalent with an XLR connector The second data pair in the recommended cable type is not used by the Relev Spot luminaire and should be capped off and tied back for future service D...

Страница 6: ...following wire color code chart Wire Color Code International Standard Wire Color Code US Standard Connection Type Terminal Green Yellow Green Earth Ground Blue White Neutral N Brown Black Line Live...

Страница 7: ...luminaires whether or not they utilize LEDs from the same production batch Operating in Direct Mode bypasses this calibration and multiple luminaires may produce slightly different outputs when contr...

Страница 8: ...aire is recommended to ensure optimal performance for the life of the luminaire Note Any service or maintenance that you perform on your Relev Spot luminaire is at your own risk WARNING RISK OF DEATH...

Отзывы: