background image

2

SolaFrame 3000 User Manual

Help from Technical Services

If you are having difficulties and your problem is not addressed by this document, try the ETC
support website at

support.etcconnect.com

or the High End Systems product website at

etcconnect.com/Products/Live-Events

. If none of these resources are sufficient, contact ETC

Technical Services directly at one of the offices identified below. Emergency service is available
from all offices outside of normal business hours.

When calling for help, take these steps first:

Prepare a detailed description of the problem

Go near the equipment for troubleshooting

Find your notification number if you have called in previously

ETC, Inc.

Americas

Technical Services Department
3031 Pleasant View Road
Middleton, WI 53562
800-775-4382 (USA, toll-free)
+1-608 831-4116

[email protected]

ETC Gm bH

Germany, Austria, Switzerland,
Eastern Europe, and Russia

Technical Services Department
Ohmstrasse 3
83607 Holzkirchen, Germany
+49 (80 24) 47 00-0

[email protected]

ETC Austin

High End Systems Products

Technical Services Department
2105 Gracy Farms Lane
Austin, TX 78758 USA
800-890-8989 (USA, toll-free)
+1-512 836-2242

[email protected]

ETC France

France

Zone Urbaparc -
Bâtiment E
6 Boulevard de la Libération
Saint-Denis, 93200
+33 1 4243 3535

[email protected]

ETC Ltd

Europe, Middle East, and Africa

Technical Services Department
26-28 Victoria Industrial Estate
Victoria Road,
London W3 6UU England
+44 (0)20 8896 1000

[email protected]

ETC Asia

Asia

Technical Services Department
Room 1801, 18/F
Tower 1, Phase 1 Enterprise Square
9 Sheung Yuet Road
Kowloon Bay, Kowloon, Hong Kong
+852 2799 1220

[email protected]

Содержание High End Systems SolaFrame 3000

Страница 1: ...High End Systems SolaFrame 3000 Automated Luminaire User Manual Version 1 3 10 Part Number 2581M1200 1 3 10 Rev A Released 2021 02 ...

Страница 2: ...arks both marked and not marked are the property of their respective owners You can find complete High End Systems terms and conditions and warranty information at etcconnect com Support Warranty aspx ETC intends this document whether printed or electronic to be provided in its entirety ...

Страница 3: ...ixture Overview 6 Install the Fixture 7 Power 10 Input and Power Factor 10 Connector Specification 10 DMX Control 11 DMX Connector Pinout 11 Connect DMX Cables to Fixture 12 DMX Control and Ethernet Output 12 Terminate DMX 12 Set the DMX Start Address 13 DMX Channels 13 Ethernet Control 14 Connect Ethernet Cables to a Fixture 14 Ethernet Control and DMX Thru 15 Terminate DMX 15 ...

Страница 4: ... Navigate the User Interface 16 Set Fixture Parameters 17 DMX Address 17 Info Menu 17 Set Menu 18 Test Menu 22 Preset Menu 23 Error Codes 24 Maintenance 27 Clean the Fixture 27 Replace the Fuse 27 Compliance 28 FCC Part 15 Class A 28 Declarations of Conformity 29 ii SolaFrame 3000 User Manual ...

Страница 5: ...l note caution and warning symbols appear in margins throughout this manual to highlight important messages Note Notes are helpful hints and information that is supplemental to the main text CAUTION Hot Surfaces This statement indicates that while operating equipment surfaces may reach very high temperatures Allow the fixture to cool before handling or servicing CAUTION A Caution statement indicat...

Страница 6: ...Middleton WI 53562 800 775 4382 USA toll free 1 608 831 4116 service etcconnect com ETC GmbH Germany Austria Switzerland Eastern Europe and Russia Technical Services Department Ohmstrasse 3 83607 Holzkirchen Germany 49 80 24 47 00 0 techserv germany etcconnect com ETC Austin High End Systems Products Technical Services Department 2105 Gracy Farms Lane Austin TX 78758 USA 800 890 8989 USA toll free...

Страница 7: ... mais doit être déposé dans une collecte de déchets électroniques ou dans un point de collecte Operate indoors only not where this product would be exposed to the weather Ne fonctionne qu à l intérieur pas là où ce produit serait exposé aux intempéries WARNING Note the following safety warnings before use This equipment is designed for operation by qualified personnel only Replace fuses with the s...

Страница 8: ...mable Distance minimum entre la tête du luminaire et les matériaux combustibles 0 1 m 4 0 in Distance minimale avec les objets éclairés 2 0 m 6 56 ft WARNING RISK OF ELECTRIC SHOCK Do not operate this device with the cover open Disconnect the fixture from power and DMX and allow it to cool before performing any cleaning and maintenance AVERTISSEMENT RISQUE DE CHOC ÉLÉCTRIQUE N utilisez pas cet app...

Страница 9: ...fixture Any modifications will void the warranty This manual describes the proper installation and operation of this fixture Using this fixture in any way other than the intended use may cause damage and void the warranty When the fixture has been stored or transported in cold temperatures allow it to warm to room temperature for a minimum of one hour before applying power Applying power to a cold...

Страница 10: ...3000 fixture see the technical data sheet etcconnect com Products Live Events Lighting Fixtures SolaFrame 3000 Documentation aspx 2 4 5 1 3 6 10 9 11 7 8 12 1 Lens 2 Tilt lock 3 Display 4 Navigation controls 5 Pan lock 6 Handle 7 Power In 8 USB 9 Fuse 10 DMX In 11 DMX Out 12 Ethernet ports x2 ...

Страница 11: ...ualified personnel AVERTISSEMENT Boîtier NEMA de type 1 utilisation en intérieur emplacements secs uniquement Ne l utilisez pas en extérieur Ce projecteur est conçu pour être utilisé dans des environnements où l humidité ne dépasse pas 90 sans condensation L installation doit toujours être sécurisée par une fixation de sécurité auxiliaire Un câble de sécurité approprié est fourni La fixation du câ...

Страница 12: ...ction The installation must only be carried out by qualified personnel ATTENTION Respectez tous les règlements locaux et toutes les pratiques recommandées par l autorité compétente L installation doit être effectuée uniquement par du personnel qualifié You can install the fixture in any of the orientations shown below ...

Страница 13: ...teps 1 through 3 for the second clamp and bracket 5 Attach the provided safety cable through the attachment point on the bottom of the fixture upper enclosure and secure to the trussing system or other safe installation point Follow local codes and recommended safety standards for securing the fixture to the installation location 6 Attach the fixture to the installation location using the installe...

Страница 14: ... Shock and Fire Assemble a grounding type attachment plug with integral cord grip that is within the voltage and amperage rating of this luminaire AVERTISSEMENT Risque de choc et d incendie Assurez vous d utiliser une prise de mise à la terre avec décharge de traction intégrée qui respecte la tension et l ampérage de ce luminaire A power input cable with powerCON TRUE1 TOP input to bare ends is pr...

Страница 15: ...wo XLR termination receptacles are available one for connection of DMX Input and one for DMX Out used when daisy chaining to additional fixtures on the DMX control bus DMX Connector Pinout For DMX Input the DMX cable must have a XLR plug connector on one end of the cable that connects to the fixture When daisy chaining DMX to the next device prepare a DMX cable with a XLR socket connector on one e...

Страница 16: ... DMX with a 120 Ohm resistor DMX 512 Belden 9729 or equivalent DMX 512 control source DMX Control and Ethernet Output You can use DMX 512 control and Ethernet output When a fixture is set up to receive DMX 512 control input it converts the signal to Art Net on IP10 and sends the signal to the Ethernet port continuing the Art Net on IP10 signal to the next fixture in the control run Terminate DMX U...

Страница 17: ...ol source Modify the fixture DMX start address on the user interface located on the upper enclosure See DMX Address on page 17 Example The SolaFrame 3000 has 49 channels If you set the DMX starting address of the first fixture to 1 you could set the second fixture to 50 49 1 the third to 99 49 50 and so on DMX Channels The most current DMX Map data for the SolaFrame 3000 can be found on the ETC we...

Страница 18: ...m the Ethernet control source to one of the Ethernet ports on the first fixture in the Ethernet control run 2 Connect the first fixture to a second fixture by connecting a cable from the second Ethernet port on the first fixture to one of the Ethernet ports on the second fixture 3 Continue linking the remaining fixtures by connecting a cable from Ethernet port to Ethernet port on the fixtures on t...

Страница 19: ...nto the DMX output receptacle of the last fixture in the DMX control run This plug is available and sold separately Contact your authorized dealer or ETC for ordering information etcconnect com contactETC Set the DMX Start Address Give each fixture a unique DMX starting address so that the correct fixture responds to the control signals This DMX start address is the channel number from which the f...

Страница 20: ...r 2 Browse the menu by pressing the up down left or right navigation buttons 3 Press the Enter button to select a menu item 4 Modify the selection by pressing the up down left or right navigation buttons according to the selection 5 Press the Enter button to confirm a modified selection 6 To exit the menu press the MODE ESC button Note If you press the Enter button to confirm a selection and push ...

Страница 21: ...rs XXXX Hours Running time of the fixture from the last time that the run time value was reset shown in hours h LED Hours XXXX Hours Total running time of the fixture LEDs shown in hours h Timer PIN Timer PIN XXX You must enter the Timer PIN in order to access the Clr Last Run menu item The default Timer PIN is 038 Clr Last Run ON OFF This password protected menu item resets the Last Run Hrs value...

Страница 22: ...is overheating View Fan Speeds Navigate Main Menu Info Fan Speed Displays the speeds of the fixture s fans in RPM View Sensor Status Navigate Main Menu Info LED Sensor Displays the status of the sensors which can help you to determine whether the fixture is recognizing the movement and position of the wheel The display toggles between ON and OFF as the magnet passes the sensor View Ethernet IP Add...

Страница 23: ... OnOP Defog OnPwr Defog Off Set when the Defogger heater for the front lens is turned on Defog OnOP Turn on Defogger when LEDs are above 0 intensity Defog OnPwr Turn on Defogger when the fixture is powered default value Defog Off Turn off Defogger Dimming Mode Standard Theatrical Set the dimming curve and pulse width modulation PWM frequency The PWM frequency is 16 kHz in Standard mode and 2 4 kHz...

Страница 24: ... XXX XXX XXX This password protected menu item lets you modify the IP address You must enter the Service PIN to access this menu item The default IP address is 002 142 058 034 Ethernet Mask IP XXX XXX XXX XXX This password protected menu item lets you modify the IP subnet mask You must enter the Service PIN to access this menu item The default IP subnet mask is 255 000 000 000 Clr Err Info ON OFF ...

Страница 25: ...Fahrenheit Update Fixture Firmware Using the USB Port Navigate Main Menu Set USB Update Fixture firmware updates are available on the ETC website at etcconnect com Products Live Events 1 Save the firmware update file to a USB drive 2 Insert the USB drive in the fixture base see Fixture Overview on page 6 for the USB port location 3 On the Main Menu select Set USB Update The fixture reads the USB d...

Страница 26: ...play indicates Running and the fixture automatically runs a self test procedure testing each of the functions Press MODE ESC button to end the self test and return the display to the previous menu Test an Individual Channel Navigate Main Menu Test Test Channel Run a self test program on individual channels The default value is Control Select a different channel to run a self test on that channel M...

Страница 27: ...g scenes into programs and then assigning the programs to Program Partitions for playback For information about the Preset menu access the High End Systems Preset Menu Guide from the ETC website support etcconnect com Source_Articles HES Sola_ Series_Fixtures High_End_Systems_Preset_Menu_Guide ...

Страница 28: ... magnetic sensor failure the stepper motor is defective or the related IC driver on the main PCB has failed the Animation Rotating wheel is not located in the default position after the reset Blade Rot This message displays after the reset of the fixture if any of the following conditions exist the magnetic indexing circuit malfunctions optical or magnetic sensor failure the stepper motor is defec...

Страница 29: ...any of the following conditions exist the magnetic indexing circuit malfunctions optical or magnetic sensor failure the stepper motor is defective or the related IC driver on the main PCB has failed Gobo Wheel 1 is not located in the default position after the reset Gobo 2 This message displays after the reset of the fixture if any of the following conditions exist the magnetic indexing circuit ma...

Страница 30: ... the related IC driver on the main PCB has failed the fixture has a frost installed in the prism slot and the Prism Frost Sel parameter is not set to Dual Frost Mode the Prism wheel is not located in the default position after the reset Tilt movement This message displays after the reset of the fixture if any of the following conditions exist the fixture head magnetic indexing circuit malfunctions...

Страница 31: ...oss of output due to accumulation of dust dirt on the lens Never use alcohol or solvents 2 Clean the fans regularly to ensure maximum airflow and efficient cooling This will ensure that the light source operates in the best possible condition Replace the Fuse WARNING Replace fuses with the specified type and rating only AVERTISSEMENT Remplacez les fusibles uniquement par le type et le calibre indi...

Страница 32: ...use undesired operation Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed a...

Страница 33: ...utside and indoor EN 62471 2008 Photobiological safety of lamps and lamp systems EN 61347 1 2015 Lamp controlgear General and safety requirements EN 61347 2 13 2014 Lamp controlgear Particular requirements for d c or a c supplied electronic controlgear for LED modules Electromagnetic Compatibility Directive EMCD 2014 30 EU EN 55015 2013 A1 2015 Limits and methods of measurement of radio disturbanc...

Страница 34: ...cular requirements for d c or a c supplied electronic controlgear for LED modules Electromagnetic Compatibility Directive EMCD 2014 30 EU EN 55015 2013 A1 2015 Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment EN 61547 2009 Equipment for general lighting purposes EMC immunity requirements EN 61000 3 2 2014 Electromagnetic compatibil...

Страница 35: ...Compliance 31 ...

Страница 36: ...re New York NY Orlando FL Los Angeles CA Austin TX Web etcconnect com Support support etcconnect com Contact etcconnect com contactETC 2021 ETC Inc Trademark and patent info etcconnect com ip Product information and specifications subject to change ETC intends this document to be provided in its entirety 2581M1200 1 3 10 Rev A Released 2021 02 ...

Отзывы: