10
SolaFrame 3000 User Manual
Power
Input and Power Factor
VAC
Amps
Hz
Watts
VA
PF
100
14.7
50
1471
1461
0.99
120
11.8
60
1420
1416
0.99
200
6.6
50
1323
1322
0.99
208
6.3
60
1322
1326
0.99
220
6.0
50
1321
1346
0.99
240
5.5
60
1316
1324
0.98
CAUTION:
Using this fixture below 100 V on a 15 A breaker may cause the
breaker to trip. Ensure that the circuit can handle the fixture's maximum
potential draw before you connect it.
Connector Specification
WARNING:
Risk of Shock and Fire. Assemble a grounding-type attachment
plug with integral cord grip that is within the voltage and amperage rating
of this luminaire.
AVERTISSEMENT :
Risque de choc et d'incendie. Assurez-vous d'utiliser
une prise de mise à la terre avec décharge de traction intégrée qui respecte
la tension et l'ampérage de ce luminaire.
A power input cable with powerCON
®
TRUE1
®
TOP input to bare ends is provided. Install a
suitable connector to meet the installation requirements. See the following wire color code
chart:
Wire Color Code (EU) Wire Color Code (US Standard) Connection type Terminal
Green/Yellow
Green
Earth/Ground
Blue
White
Neutral
N
Brown
Black
Line (Live)
L