Configure the Fixture
19
Parameter
Value
Description
Tilt Reverse
•
ON
•
OFF
Reverse the tilt movement of the fixture. The default value is
OFF.
Pan Degree
•
630
•
540
Change the pan rotation of the fixture from the default
setting of 540 degrees to 630 degrees.
Encoders
•
ON
•
OFF
Turn on or off the encoder feedback for pan and tilt
movement. You may want to turn off encoders when
working on a fixture so that you can move pan and tilt
without the fixture automatically moving back to position.
Pan/Tilt Spd
1–4
Set the speed (scan mode) of pan and tilt movement. The
default value is 1. Use this parameter to make fine
adjustments to pan and tilt movement in order to correct for
mis-stepping when the fixture is installed on its side (side-
hung, or "Outrig").
Hibernation
•
OFF
•
1–99 minutes
Hibernation mode forces the LEDs and stepper motors to
power off when the fixture loses DMX control signal for a set
period of time. The default time setting is 15 minutes.
Defogger
•
Defog OnOP
•
Defog OnPwr
•
Defog Off
Set when the Defogger (heater for the front lens) is turned
on:
•
Defog OnOP: Turn on Defogger when LEDs are above
0% intensity
•
Defog OnPwr: Turn on Defogger when the fixture is
powered (default value)
•
Defog Off: Turn off Defogger
Dimming Mode
•
Standard
•
Theatrical
Set the dimming curve and pulse width modulation (PWM)
frequency. The PWM frequency is 16 kHz in Standard mode
and 2.4 kHz in Theatrical mode. The default value is
Standard.
Out Rig Mode
•
ON
•
OFF
Turn on when the fixture is installed on its side (side hung, or
"Outrig"). This parameter reduces the speed of pan and tilt
movement to correct for mis-stepping.
P/T Home Mode
•
Standard
•
Tilt First
•
Pan First
Set the order in which pan and tilt homing is performed.
•
Standard: the pan and tilt home procedures run
simultaneously.
•
Tilt First: the tilt home procedure runs to completion,
then the pan home procedure begins.
•
Pan First: the pan home procedure runs to completion,
then the tilt home procedure begins.
Prism/Frost Sel
•
Prism Mode
•
Dual Frost
Mode
If you have installed a frost in the prism slot, select Dual
Frost Mode so that the fixture will home appropriately. The
default setting is Prism Mode.