7.4 - ALARMS SETTING
3 - OVER: Overdosing alarm. For any kind of problems may occur in the plant (wrong calibration, dirty or broken probe,
etc.) if the pump doesn't reach the Setpoint in OVER ALARM TIME, the pump stops the dosing. On the display Alarm message
It is possibleto to plan three different types of alarm pump:
1 - MAX: User can set at which maximum value the pump has to go in alarm mode. When the pump will go over this
value, on the display, Alarm message will flash, Alarm Led will flash.
2 - min: User can set at which minimum value the pump has to go in alarm mode. When the pump will go over this
value, on the display, Alarm message will flash, Alarm Led will flash.
will flash, Alarm Led will flash.
When ALARM menu is reached, press OK to enter in submenus
To enter in ALARM menu follow the procedure described in paragraph
7.1 - PUMP SETUP.
7.4.3 - Overdosing Alarm setting
On the display will appear OVER and time counter (h:min) will flash.
alarm.
Press + and - to adjust the time, over which the pump will go in
7.4.1 - Maximum Alarm setting
On the display will appear MAX and the value of measure will flash.
Press OK to confirm and to save data.
Press + and - to adjust the maximum value of the measure
7.4.2 - Minimum Alarm setting
On the display will appear "min" and the value of measure will flash.
Press OK to confirm and to save data.
Press + and - to adjust the minimum value of the measure
Press ESC to return in measure mode.
Press OK to confirm and to save data.
This will end the alarm seeting.