ETAS
Hardware Description
ETK-S20.1
-
User Guide
26
4.16
ETK-S20.1 Usage at ES89x Modules
4.16.1
Microcontroller Compatibility
Not all ETK-S20.1 versions with all microcontrollers are compatible for usage
with ES89x modules. Please check the microcontroller support in chapter “Soft
36.
4.16.2
Wiring
To connect the ETK-S20.1 with ES89x modules the CBE260 cable and the
CBAE360 adapter are needed (see chapter 5.2 on
29).
4.16.3
Getting Started
The LED at the FETK / Gigabit interface of the ES891 lights red, if the connected
ETK is not prepared to use at ES89x modules. A HSP update is needed.
Check for update
1. Connect the ETK-S20.1 to an ES89x module.
- If the FETK / Gigabit interface LED at the ES891 front panel
lights red, the connected ETK is not prepared to use at
ES89x modules.
A HSP update is needed.
- If the FETK / Gigabit interface LED at the ES891 front panel
lights green, the connected ETK is prepared to use at ES89x
modules.
A HSP update is not needed.
Special HSP Update
1. Connect the ETK to another ETAS module (only ES59x or
ES910 are suitable).
2. Update the ETK with HSP.
4.16.4
A2L File
Regardless of the used module (ES59x, ES910, ES89x) the same A2L file at the
ETK will be working.
NOTE
If the power supply or the Ethernet connection will be interrupted during this
(first) special firmware update the ETK will be corrupted! Please contact
ETAS.
NOTE
If once updated, the ETK-S20.1 can be used as DualMode ETK both at ES89x
modules and at ES59x modules.