ETAS ES593.1-D Скачать руководство пользователя страница 3

ETAS

 

Contents

Contents

ES593.1-D

 

-

 

User Guide

3

1

About this Document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

1.1

Classification of Safety Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   6

1.2

Presentation of Instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   6

1.3

Typographical Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   7

1.4

Presentation of Supporting Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   7

2

 About this Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

2.1

Scope of Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   8

2.2

Additional Information  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   8

3

Basic Safety Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

3.1

General Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   9

3.2

Requirements for Users and Duties for Operators  . . . . . . . . . . . . . . . . . . . . . . . . . . . .   9

3.3

Intended Use. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   9

4

Hardware Description  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   14

4.1

Overview  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  14

4.2

Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  14

4.3

Housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  15

4.4

Interfaces  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  15
4.4.1

Front Panel  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  15

4.4.2

Back Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  16

4.5

LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  16
4.5.1

Flash Codes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  16

4.5.2

Operational State of the Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  17

4.5.3

Functional State of Individual Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . .  18

5

Functional Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   20

5.1

Block Diagram  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  20

5.2

Power Supply (7-29V DC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  20

5.3

Ethernet Switch  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  20
5.3.1

Host Port (HOST) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  21

5.3.2

Ethernet Ports (ETH1 and ETH2)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  21

5.4

ETK Interface (ETK). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  22
5.4.1

Initialization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  22

5.4.2

Operating Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  22

5.5

CAN Interface (CAN1/CAN3, CAN2/CAN4)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  23
5.5.1

Operating Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  23

5.5.2

Feature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  23

5.5.3

"Wake-Up" Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  23

5.5.4

„CAN Pre-Buffering“ Function (Buffering of CAN Frames) . . . . . . . . . . . .  23

5.5.5

Bus Terminating Resistor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  24

5.6

Time Synchronization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  24

5.7

"Wake-Up" Function. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  24

Contents

Содержание ES593.1-D

Страница 1: ...ETAS ES593 1 D Prototyping and Interface Module User Guide ...

Страница 2: ...single license Using and copying is only allowed in concurrence with the specifications stipu lated in the contract Under no circumstances may any part of this document be copied reproduced transmitted stored in a retrieval system or translated into another language without the express written permission of ETAS GmbH Copyright 2021 ETAS GmbH Stuttgart The names and designations used in this docume...

Страница 3: ...sing 15 4 4 Interfaces 15 4 4 1 Front Panel 15 4 4 2 Back Panel 16 4 5 LEDs 16 4 5 1 Flash Codes 16 4 5 2 Operational State of the Module 17 4 5 3 Functional State of Individual Interfaces 18 5 Functional Description 20 5 1 Block Diagram 20 5 2 Power Supply 7 29V DC 20 5 3 Ethernet Switch 20 5 3 1 Host Port HOST 21 5 3 2 Ethernet Ports ETH1 and ETH2 21 5 4 ETK Interface ETK 22 5 4 1 Initialization...

Страница 4: ... selected via Network Manager 34 7 3 2 Search for Ethernet Hardware Fails 35 7 3 3 Personal Firewall Blocks Communication 37 8 Technical Data 42 8 1 General Data 42 8 1 1 Product Labeling 42 8 1 2 Fulfilled Standards and Norms 43 8 1 3 Environmental Conditions 43 8 1 4 Maintenance the Product 43 8 1 5 Cleaning the Product 43 8 1 6 Mechanical Data 43 8 2 RoHS Conformity 44 8 3 CE conformity 44 8 4 ...

Страница 5: ... 9 3 2 Ethernet Connection Cable 58 9 3 3 Ethernet Connection Adapter Cable 58 9 4 ETK Interface Cable 59 9 5 CAN LIN Interface Cable and Adapter 59 9 5 1 CAN Interface Cable 59 9 5 2 CBCFI100 Cable 61 9 5 3 CAN Termination Resistor 63 10 Ordering Information 64 10 1 ES593 1 D 64 10 1 1 ES593 1 D with CBP120 Power Supply Cable 64 10 1 2 ES593 1 D with CBP1205 Power Supply Cable 64 10 2 Cable and A...

Страница 6: ...ry steps for his are in a step by step guide Target definition 1 Step 1 2 Step 2 3 Step 3 Result DANGER indicates a hazardous situation with a high risk of death or serious injury if not avoided WARNING indicates a hazardous situation of medium risk which could result in death or serious injury if not avoided CAUTION indicates a hazardous situation of low risk which may result in minor or moder at...

Страница 7: ... Guide 7 1 3 Typographical Conventions Hardware 1 4 Presentation of Supporting Information Bold Menu commands buttons labels of the product Italic Emphasis on content and newly introduced terms NOTE Contains additional supporting information ...

Страница 8: ...whether the module was delivered with all required components and cables see chapter 10 1 on page 64 Additional cables and adapters can be obtained separately from ETAS A list of available accessories and their order designation is located in chapter Cable and Accessoires on page 65 of this manual or in the ETAS product catalog 2 2 Additional Information The configuration instructions for the modu...

Страница 9: ...alth or damages to property General safety at work The existing regulations for safety at work and accident prevention must be followed All applicable regulations and statutes regarding operation must be strictly followed when using this product 3 3 Intended Use Application area of the product This product was developed and approved for applications in the automotive sector The module is suitable ...

Страница 10: ...eing followed see the information in the chapter Technical data Do not apply any voltages to the connections of the module that do not correspond to the specifications of the respective connection Power supply The power supply for the product must be safely disconnected from the supply voltage For example use a car battery or a suitable lab power supply Use only lab power supplies with double prot...

Страница 11: ...cables Cables may be repaired only by ETAS Never apply force to insert a plug into a socket Ensure that there is no contamination in and on the connection that the plug fits the socket and that you correctly aligned the plugs with the connection Requirements for the location Position the module or the module stack on a smooth level and solid underground The module or the module stack must always b...

Страница 12: ...t the cable of the module or any other cables Maintenance The product is maintenance free Repair If an ETAS hardware product should require a repair return the product to ETAS Cleaning the module housing Use a dry or lightly moistened soft lint free cloth for cleaning the module housing Do not user any sprays solvents or abrasive cleaners which could dam age the housing Ensure that no moisture ent...

Страница 13: ...ormation about cabling see the User s Guide of the module CAUTION Potential equalization in the vehicle is possible via the shield of the connecting cables of the modules Install the modules only at locations with the same electrical potential or iso late the modules from the installation location ...

Страница 14: ... that have their own Ethernet interface can be connected directly with an ES593 1 D mod ule and communicate with INCA via Ethernet The ES593 1 D has the ECU inter faces ETK and CAN Two of the four CAN interfaces additionally offer a Wake Up function and buf fer CAN messages until a ES720 Drive Recorder connected to the ES593 1 D starts the data recording If necessary systems can be cascaded using ...

Страница 15: ...ironmental conditions temperature EMC Wide supply voltage range High mechanical stability and durability Part of the ETAS Tool Suite For the complete technical data of the ES593 1 D refer to the chapter Techni cal Data on page 42 4 3 Housing Standard housing with interfaces on the front and rear of the device is used for the ES593 1 D The sturdy metal housing of the ES593 1 D has nonskid plastic f...

Страница 16: ... 5 LEDs 4 5 1 Flash Codes The ES593 1 D is equipped with LEDs which indicate the operational state of the module as well as with LEDs which display the function of individual inter faces The following flash codes are used for the LEDs Fig 4 4 Flash Codes 7 29V 7A Flash code 1 On Off Off On LED 1 3 4 2 t s Off On Off On Off On Flash code 2 Flash code 4 Flash code 5 Flash code 3 ...

Страница 17: ...code 3 The module is on Standby the power consumption is minimal The module needs a wakeup event to enter the nor mal operation mode Off The module is not powered ER Red Module is currently booting or booting was unsuccessful Red flashing Flash code 1 Internal device software error core file created Red flashing Flash code 2 Firmware update is being executed Off No error C Red Temperature inside t...

Страница 18: ... mas ter the module is not synchronized externally Blue flashing Flash code 5 semi and fully bright alternately The module is a synchronization slave the module is synchronized externallyat the HOST or at the ETH1 or at the ETH2 port Off No synchronization MODE Green Function CAN Pre Buffering for the interfaces CAN1 and or CAN2 is acti vated in INCA HWC Off Function CAN Pre Buffering for the inte...

Страница 19: ...odule at the power supply output at the interface ETH1 Off Power supply output at the interface ETH1 is switched off LED Display Functional State ETH2 Yellow flashing Communication at the interface ETH2 Off Communication interrupted POUT Green Power supply output at the interface ETH2 is switched on Red Overload by connected module at the power supply output at the interface ETH2 Off Power supply ...

Страница 20: ...itch The integrated Ethernet switch is used for the connection of the ES593 1 D module and other measurement or interface modules to a user PC Data from the connected modules is acquired synchronously ETAS device synchroniza tion see chapter 5 6 on page 24 The Ethernet switch can be cascaded with other network modules so that you can create larger blocks of measurement and interface modules NOTE T...

Страница 21: ...provides two downstream Ethernet interfaces for fur ther modules ECUs that have an XETK or their own Ethernet interface can be connected directly with a ES593 1 D module and communicate with the cali bration software via XCP on Ethernet Module Network The downstream Ethernet interfaces ETH1 and ETH2 connect the ES593 1 D module to other ES600 modules measurement calibration and rapid prototyp ing ...

Страница 22: ...d for compatibility reasons The following table lists the features of the individual operating modes for the ETK interface Basic Operating Mode When using the Basic operating mode older projects are supported without any change All ETK interface hardware can be used Compatibility Operating Mode An important feature of the Compatibility operating mode is block transfer The block transfer between th...

Страница 23: ...he ES593 1 D can be operated in High Speed CAN link ISO 11898 2 5 5 2 Feature You can find a list of CAN applications supported by the ES593 1 D in chapter 8 9 2 on page 46 5 5 3 Wake Up Function The CAN interfaces CAN1 and CAN2 support the Wake Up function see chap ter 5 7 on page 24 5 5 4 CAN Pre Buffering Function Buffering of CAN Frames The functions Wake Up and CAN Pre Buffering are supported...

Страница 24: ...me synchronization unit of the ES593 1 D master synchronizes the con nected modules via the Ethernet lines The synchronization signal is relayed to connected modules at the ETH1 and ETH2 interfaces SYNC OUT The slave modules adapt to the clock pulse specified by the master module The periodic synchronization signal is superimposed onto the Ethernet signals without affecting data transfer This excl...

Страница 25: ...ace of the ES593 1 D see chapter 6 4 on page 31 The Wake Up function can be configured activated and deactivated for both interfaces CAN1 and CAN2 independently of one another in the application software INCA HWC or in the web interface 5 8 Firmware Update The firmware of the ES593 1 D can be updated by the user so that future ver sions of the module can also be implemented The firmware is updated...

Страница 26: ...vice is already contained in the housing and is easily accessible To fasten the ES593 1 D housing 1 Remove the plastic feet from the bottom of the module by pushing a minus screwdriver between the housing bottom and the plastic foot 2 Lifting off the plastic foot using the screwdriver as a lever Fig 6 1 Levering Off the Plastic Foot 3 A threaded hole will become visible under the plastic foot The ...

Страница 27: ...of the ES593 1 D so a further module can be attached This makes the assembly slits for the T Brackets accessible You can attach a further module under the ES593 1 D 2 Remove the four plastic feet on the relevant side of the second module 3 Turn the seals of the T Brackets so they are at a right angle to the longitudinal axis of the brackets 4 Click two brackets into the assembly slits on one long ...

Страница 28: ...her two T Brackets into the assembly slits on the opposite long side of the device 8 Lock these brackets too 9 If you would like to stack further modules repeat this proce dure with the next module 6 2 Applications For applications the ES593 1 Dhas direct access to XETK ECUs and to ECUs and vehicle buses NOTE You can find a list of applications supported by the ES593 1 D in chapter 8 9 2 on page 4...

Страница 29: ...205 2 Host connecting cable CBE100 3 PC connecting and Power supply cable ES4xx ES63x CBEP420 CBEP425 4 Ethernet connecting cable CBE130 CBE140 5 XETK connecting cable with XETK interface cable CBAE330 and CBE230 6 ETK connecting cable CBM150 7 CAN LIN FlexRay connecting cable CBCFI100 NOTE Be sure to check that the ports carry no voltage before starting the cabling LIN CAN Ethernet Application 4 ...

Страница 30: ...urrent consumption of the ES593 1 D and its supply voltage range The admissible values are listed in section 8 10 1 on page 47 6 3 3 ETH1 and ETH2 Port To connect the ES593 1 D module with other modules ETH1 and ETH2 port you require the CBE130 cable Simple Module Network A simple module network consists of a single ES593 1 D module with con nected network or measure modules ES59x measure modules ...

Страница 31: ...odule network The following figure shows an example of a module network with three cascaded ES59x modules Fig 6 5 Example of a Module Network To connect an ES59x module with other ES59x modules 1 Connect the HOST port of the subordinate ES59x module with the ETH1 port or with the ETH2 port of the superordinate ES593 1 D module or 1 connect the HOST port of the subordinate ES59x module with the ETH...

Страница 32: ...the HSP program on the PC 3 Click Hardware Search 4 Highlight the ES593 1 D configured in the Hardware window 5 Right click System Configuration The default web browser launches the web interface for con figuring the ES593 1 D with the current IP address of the mod ule in the address field The home page of the ES593 1 D web interface is displayed 6 4 3 Configuring the Wake Up Function To configure...

Страница 33: ...ons The ES593 1 D is not found with Search for Hardware in INCA Did you install the INCA version required Check that the INCA software installed on your PC corresponds to the requirements listed in section 8 9 2 on page 46 Did you install the INCA ES5xx Add On version required Check that the INCA ES5xx Add On installed on your PC corresponds to the requirements listed in section 8 9 2 on page 46 D...

Страница 34: ... with your network administrator The LIN interface is not initialized Have you installed the INCA LIN Add On Check that the INCA LIN Add On installed on your PC corresponds to the requirements listed in section 8 9 2 on page 46 Measurement does not start Are you being prompted to carry out an update in the INCA Monitorlog Update the modules Is there no data from the module Check that your power su...

Страница 35: ...IPAutoconfiguratio nEnabled to 1 to enable the APIPA mechanism You may find several instances of this key in the Windows reg istry which either apply to the TCP IP service in general or to a specific network adapter You only need to change the value for the corresponding network adapter 5 Close the registry editor 6 Restart your workstation in order to make your changes take effect 7 3 2 Search fo...

Страница 36: ...r Logical Network If you use more than one PC or notebook for accessing the same ETAS hard ware the network adapters used must be configured to use the same logical network If this is not possible it is necessary to switch the ETAS hardware off and on again between different sessions repowering Cause Device driver for network card not in operation It is possible that the device driver of a network...

Страница 37: ...errupts the Ethernet connection This can be prevented by setting the registry key autodisconnect To set the registry key autodisconnect 1 Open the Registry Editor 2 Select under HKEY_LOCAL_MACHINE SYSTEM ControlSet001 Services lanmanserver paramete rs the Registry Key autodisconnect and change its value to 0xffffffff 7 3 3 Personal Firewall Blocks Communication Cause Permissions given through the ...

Страница 38: ... On many other systems it is very common to have personal firewall software from third party vendors such as Symantec McAffee or BlackIce installed The proceedings in configuring the ports might differ for each personal firewall software used Therefore please refer to the user documentation of your personal firewall soft ware for further details As an example for a firewall configuration you will ...

Страница 39: ...ity Alert dialog window you can unblock ETAS products in advance To unblock ETAS products in the firewall control 1 From the Windows Start Menu select Settings Control Panel 2 In the control panel double click the Windows Firewall icon 3 In the Windows Firewall dialog window open the Exceptions tab This tab lists the exceptions not blocked by the firewall Use Add Program or Edit to add new program...

Страница 40: ... with an ETAS software product requires Write and Modify privileges within the ETAS ETASData and ETAS temporary directories Otherwise an error message opens if the product is started and a database is opened In that case no correct operation of the ETAS product is possible because the data base file and some ini files are modified during operation The ETAS software has to be installed by an admini...

Страница 41: ...rity Alert dialog window activate the option For this program don t show this message again 2 Click OK to close the window An administrator has to select the respective ETAS software in the Exceptions tab of the Windows Firewall dialog window to avoid further problems regarding hardware access with that ETAS product ...

Страница 42: ...ata 8 1 1 Product Labeling The following symbols are used for product labeling Symbol Description Prior to operating the product be sure to read the user s guide SN 1234567 Serial number seven digit Vx y z Hardware version of the product F 00K 123 456 Ordering number of the product see chapter 10 1 on page 64 Operating voltage range DC xy A Current consumption max Marking for CE conformity Chapter...

Страница 43: ...tandard residential com mercial and light industrial environ ments EN 60 529 Degrees of protection provided by enclosures IP code EN 60 068 2 32 Basic environmental testing proce dures part 2 tests test Ed free fall Temperature range operation 40 C bis 70 C 40 F bis 158 F Temperature range storage module without packaging 40 C bis 85 C 40 F bis 185 F Relative humidity non condensing 0 to 85 operat...

Страница 44: ...ropean Union The CE Declaration of Conformity for the product is available upon request 8 4 UKCA conformity With the UKCA mark attached to the product or its packaging ETAS confirms that the product corresponds to the product specific applicable standards and directives of Great Britain The UKCA declaration of conformity for the product is available on request 8 5 KCC conformity With the KC mark a...

Страница 45: ... Detailed information is located in the ETAS download center in the customer information REACH Declaration www etas com Reach This information is continuously being updated 8 8 Use of Open Source Software The product uses Open Source Software OSS This software is installed in the product at the time of delivery and does not have to be installed or updated by the user Reference shall be made to the...

Страница 46: ...are in the following versions NOTE It is imperative you disable the function which automatically switches to power saving mode on your PC network adapter when there is no data traffic on the Ethernet interface Support in Application Software Inter face Application Classifi cation 1 INCA V6 2 1 2 INCA V7 0 3 ETH XCP on Ethernet MC yes yes ETK ETK Measurement and Calibration MC yes 4 yes 5 CAN CAN M...

Страница 47: ...pstream mod ule Protection 2 Protected against polarity inversion and Load Dump protection 1 module without power supply of connected modules 2 The module may be used only with central load dump protection Anschlusstyp Upstream Anzahl 1 HOST Verbindung 10 100Base T Ethernet Protocol TCP IP Protocol Ethernet Switching Layer 2 IEEE802 3 Resolution synchronization 1 s Compatibility 1 PC ES720 Drive R...

Страница 48: ...tion ETH Min 2 A Power supply of connected mod ules ES4xx Measurement Modules ES6xx Measurement Modules XETKs Compatibility 1 Network Module ES600 Network and interface modules ES51x ES592 ES593 D ES595 Measurement modules ES4xx ES6xx ES930 1 Prototyping and Interface Module ES910 3 ECUs with XETK ECUs with Ethernet interface Third party Ethernet devices 2 1 Support of ETAS synchronization mechani...

Страница 49: ...by the module are listed in the table For more details refer to the ETAS website ETKs not supported ETKM ETK3 x ETK4 ETK6 x ETK7 0 METK1 METK2 ETK8 0 ETK8 1 ETKS1 0 A ETKS1 0 B ETKP1 0 CAN1 CAN2 CAN3 and CAN4 4 independent interfaces galvanically isolated from each other and from the other interfaces every channel separately configurable High Speed CAN Protocols CAN V2 0a Standard Identifier CAN V...

Страница 50: ...T Fig 8 3 Host Interface HOST NOTE All connectors are shown with a view of the interfaces of the ES593 1 D All shields are at case potential Pin Signal Meaning 1 UBATT Supply voltage plus 2 Ground Ground Pin Signal Meaning 1 Reserved 2 Reserved 3 Reserved 4 RX Received data plus 5 TX Send data minus 6 RX Received data minus 7 Reserved 8 TX Send data plus 2 1 1 8 ...

Страница 51: ... ETK Interface ETK Pin Signal Meaning 1 UBATT Supply voltage plus 2 UBATT Supply voltage plus 3 UBATT Supply voltage minus 4 RX Receive data plus 5 TX Send data minus 6 RX Receive data minus 7 UBATT Supply voltage minus 8 TX Send data plus Pin Signal Meaning 1 TX Send data plus 2 TX Send data minus 3 RX Received data plus 4 RX Received data minus 1 8 1 3 4 2 ...

Страница 52: ... CAN3 8 11 6 CAN Interface CAN2 CAN4 Fig 8 7 CAN Interface CAN2 and CAN4 Pin Signal Meaning 1 Reserved 2 CAN1_LOW 3 CAN1_GND_1 4 CAN3_HIGH 5 CAN3_GND 6 CAN1_GND_2 7 CAN1_HIGH 8 CAN3_LOW Pin Signal Meaning 1 Reserved 2 CAN2_LOW 3 CAN2_GND_1 4 CAN4_HIGH 5 CAN4_GND 6 CAN2_GND_2 7 CAN2_HIGH 8 CAN4_LOW 1 8 1 8 ...

Страница 53: ...ces of the ES593 1 D The maximum admissible cable lengths must be adhered to NOTE Custom cables can be produced according to your specifications For more information on custom cables please contact your local ETAS sales repre sentative DANGER Dangerous electrical voltage Connect the power cable only with a suitable vehicle battery or with a suitable lab power supply The connection to power outlets...

Страница 54: ...e Fig 9 1 Cable CBP120 2 power supply cable with standard banana plugs Side A Side B Side A Side B Pin Signal Plug Signal 1 UBATT Red UBATT 2 Ground Black Ground Order name Short name Order number Power Supply Cable Lemo 1B FGJ Banana 2fc 2mc 2 m CBP120 2 F 00K 102 584 ...

Страница 55: ...nd Black Ground Order Name Short name Order Number Power Supply Cable Lemo 1B FGJ Safety Banana 2fc 2mc 2 m CBP1205 2 F 00K 110 023 NOTE Power supply cables with safety banana plug are suitable only for connection to voltage sources with safety socket Side A Side B Order Name Short name Order Number Ethernet PC Connection Cable Lemo 1B FGG RJ45 8mc 8mc 3 m CBE100 3 F 00K 102 559 Ethernet PC Connec...

Страница 56: ... B Order Name Short name Order Number Ethernet Connection and Power Supply Cable Lemo 1B FGF Lemo 1B FGD 8mc 8mc 0m45 CBE130 0m45 F 00K 102 748 Ethernet Connection and Power Supply Cable Lemo 1B FGF Lemo 1B FGD 8mc 8mc 3 m CBE130 3 F 00K 102 587 Side A Side B Order Name Short name Order Number Ethernet Connection and Power Supply Cable with Angular Connectors Lemo 1B FMF Lemo 1B FMD 8mc 8mc 0m45 C...

Страница 57: ...ly Cable Lemo 1B FGF Lemo 1B FGL Banana 8mc 8fc 2mc 3 m CBEP420 1 3 F 00K 105 292 Side A Side B Order Name Short name Order Number Ethernet Connection and Power Supply Cable Lemo 1B FGF Lemo 1B FGL Banana 8mc 8fc 2mc 3 m CBEP425 1 3 F 00K 105 972 NOTE The wiring of the modules of the ES400 product family with each other and the cables required by the modules are described in the documentation of t...

Страница 58: ...r Name Short name Order Number Ethernet PC Connection Cable Lemo 1B FGF Lemo 1B FGL 8mc 8fc 3 m CBE400 2 3 F00K 104 920 Side A Side B Order Name Short name Order Number Ethernet PC Connection Cable Highly Flexible Lemo 1B FGF Lemo 1B FGL 8mc 8fc 0m5 CBE401 1 0m5 F00K 106 128 Side A Side B Order Name Short name Order Number Ethernet Connection Adapter Cable 1 Gbit s to 100 Mbit s Lemo 1B PHE Lemo 1...

Страница 59: ...Name Short name Order Number ETK Interface Cable 100 Mbit s Lemo 1B FFG Lemo 1B FFG 4mc 4mc 3 m CBM150 3 F 00K 102 556 ETK Interface Cable 100 Mbit s Lemo 1B FFG Lemo 1B FFG 4mc 4mc 5 m CBM150 5 F 00K 102 557 ETK Interface Cable 100 Mbit s Lemo 1B FFG Lemo 1B FFG 4mc 4mc 10 m CBM150 10 F 00K 102 553 Side A Side B Order Name Short name Order Number CAN Interface Cable OBDII J1962 Lemo 1B FGC 16mc 8...

Страница 60: ...er Name Short name Order Number CAN Interface Cable Lemo 1B FGC Banana 8mc 2mc 1m5 CBAC160 1 1m5 F00K 106 116 Side A Side B Order Name Short name Order Number CAN Interface Y Cable Lemo 1B FGC 2xDSUB 8mc 9fc 9mc 2 m K106 F 00K 001 271 Side A Side B Order Name Short name Order Number CAN Interface Y Cable Lemo 1B FGC Lemo 0S PCA Lemo 0S FFA 8mc 2fc 2mc 2 m K107 F 00K 001 272 ...

Страница 61: ...plug combination side B and C marked in gray a socket plug combination side D and E marked in black Mapping of DSUB Socket Plug Combinations to ES593 1 D If one CBCFI100 cable each is used at the interfaces CAN1 CAN3 and CAN2 CAN4 of ES593 1 D these interfaces are mapped to the DSUB socket plug combinations of both cables as follows Side B C gray Side A Side D E black Order Name Short Name Order N...

Страница 62: ...re assigned the signals of the CAN1 CAN3 interface of ES593 1 D as follows Lemo Side A DSUB Color gray Side B Side C Pin Signal Pin Signal 1 1 2 CAN1_LOW 2 CAN1_LOW 3 CAN1_GND_1 3 CAN1_GND_1 4 CAN3_HIGH 4 5 CAN3_GND 5 6 CAN1_GND_2 6 CAN1_GND_2 7 CAN1_HIGH 7 CAN1_HIGH 8 CAN3_LOW 8 9 DSUB Color black Side D Side E Pin Signal 1 2 CAN3_LOW 3 CAN3_GND 4 5 6 7 CAN3_HIGH 8 9 ...

Страница 63: ... 9 17 CBCX131 0 Termination Resistor Lemo Side A DSUB Color gray Side B Side C Pin Signal Pin Signal 1 1 2 CAN2_LOW 2 CAN2_LOW 3 CAN2_GND_1 3 CAN2_GND_1 4 CAN4_HIGH 4 5 CAN4_GND 5 6 CAN2_GND_2 6 CAN2_GND_2 7 CAN2_HIGH 7 CAN2_HIGH 8 CAN4_LOW 8 9 DSUB Color black Side D Side E Pin Signal 1 2 CAN4_LOW 3 CAN4_GND 4 5 6 7 CAN4_HIGH 8 9 Order Name Short name Order Number CAN 120 Termination Resistor 2xD...

Страница 64: ...ina RoHS leaflet_Compact_green_cn NOTE The cables for additional interfaces of the module are not part of the delivery scope and must be ordered separately see chapter 10 2 on page 65 Order Name Short Name Order Number ES593 1 D Interface Module 1xETK 2xCAN 2xLIN 2xFlexRay 1xEthernet with Safety Cable ES593 1 D S F 00K 110 424 Package Contents ES593 1 D Interface Module 1xETK 2xCAN 2xLIN 2xFlexRay...

Страница 65: ...Lemo 1B FGJ Safety Banana 2fc 2mc 2 m CBP1205 2 F 00K 110 023 Order Name Short Name Order Number Ethernet PC Connection Cable Lemo 1B FGG RJ45 8mc 8mc 3 m CBE100 3 F 00K 102 559 Ethernet PC Connection Cable Lemo 1B FGG RJ45 8mc 8mc 8 m CBE100 8 F 00K 102 571 Order Name Short Name Order Number Ethernet Connection and Power Supply Cable Lemo 1B FGF Lemo 1B FGD 8mc 8mc 0m45 CBE130 0m45 F 00K 102 748 ...

Страница 66: ...mber ETK Interface Cable 100 Mbit s Lemo 1B FFG Lemo 1B FFG 4mc 4mc 3 m CBM150 3 F 00K 102 556 ETK Interface Cable 100 Mbit s Lemo 1B FFG Lemo 1B FFG 4mc 4mc 5 m CBM150 5 F 00K 102 557 ETK Interface Cable 100 Mbit s Lemo 1B FFG Lemo 1B FFG 4mc 4mc 10 m CBM150 10 F 00K 102 553 Order Name Short Name Order Number CAN Interface Cable OBDII J1962 Lemo 1B FGC 16mc 8mc 2m5 CBAC150 2m5 F 00K 104 159 CAN I...

Страница 67: ... 2 6 Housing Accessories 10 2 7 Software Order Name Short Name Order Number T Bracket for ES600 Housing ES600_H_TB F 00K 001 925 Order Name Short Name Order Number INCA ES5xx Software Integration Package for INCA V6 2 1 and later ISW_ES5xx F 00K 106 641 ...

Страница 68: ...ails of your local sales office as well as your local technical support team and product hotlines take a look at the ETAS website Borsigstraße 24 Phone 49 711 3423 0 70469 Stuttgart Fax 49 711 3423 2106 Germany Internet www etas com ETAS subsidiaries Internet www etas com en contact php ETAS technical support Internet www etas com en hotlines php ...

Страница 69: ...g 8 4 Ethernet Interfaces ETH1 and ETH2 51 Fig 8 5 ETK Interface ETK 51 Fig 8 6 CAN Interface CAN1 and CAN3 52 Fig 8 7 CAN Interface CAN2 and CAN4 52 Fig 9 1 Cable CBP120 2 power supply cable with standard banana plugs 54 Fig 9 2 Cable CBP1205 power supply cable with safety banana plugs 55 Fig 9 3 CBE100 x Cable 55 Fig 9 4 CBE130 x Cable 56 Fig 9 5 CBE140 0m45 Cable 56 Fig 9 6 CBEP420 1 Cable 57 F...

Страница 70: ...ing Mode 22 Connecting Housing 27 Cylinder Screw M3 27 D Data Electrical 47 Mechanical 43 Technical 42 Documentation 9 E Electrical Data 47 Electrical safety 10 Error LEDs 33 ETAS Device Synchronization 24 Ethernet Switch Features 20 ETK interface 49 51 ETK Interface ETK 22 ETK Interface Operating Mode Advanced 23 Basic 22 Compatibility 22 F Feature 23 Features 14 Ethernet Switch 20 Firmware Updat...

Страница 71: ...ulation EU 45 Receive Data 51 Recycling 44 RoHS conformity China 44 European Union 44 RX 51 S Safety at work 9 10 Safety notices basic 9 Identification 8 Safety precautions 9 Scope of supply 8 Screw Thread 26 Send Data 51 Standards 43 Standards and Norms 43 Supply Voltage 51 SYNC IN 24 SYNC OUT 24 System Requirements 45 T T Bracket 27 Technical Data 42 Termination Resistor CBCX131 0 63 Time Synchr...

Отзывы: