Cleaning and maintenance
2500 h / annually
15
2.5.4
Cleaning the combustion chamber
Clean inside of the secondary combustion
chamber
Open the combustion chamber door and scrape all of
the ash from the secondary combustion chamber into
the primary combustion chamber with the poker.
Fig. 2-12: Secondary combustion chamber
Remove the combustion chamber cover in the
secondary combustion chamber.
Fig. 2-13: Combustion chamber cover
Clean tilting grate
The tilting grate cannot be rotated by hand. Therefore,
press the [De-ash]
button to de-ash the boiler. The
grate is tilted and remains in this position for approxi-
mately 15 seconds.
WARNING!
Danger of crushing due to tilting grate
When the grate is tilted, switch off the boiler with
the mains switch. This causes the grate to remain
in this position so injuries while cleaning the grate
are prevented.
Use the poker to clean the tilting grate and the
openings in it; let the ash fall down.
Fig. 2-14: Tilting grate
Do not hit the tilting grate with the poker.
Clean secondary air openings
Clean secondary air openings (above the tilting grate).
Fig. 2-15: Secondary air openings