Preliminary
checks
THE ELECTRICAL WIRINGS SHOULD BE CARRIED OUT BY AUTHORIZED AND
QUALIFIED PERSONNEL ONLY IN ACCORDANCE WITH LOCAL REGULATIONS.
Before to proceed, verify the following steps:
1.
Verify the data on nameplate.
Make sure that the electrical data on the nameplate of the motor corresponds to the
electrical supply.
2.
Verify the grounded power outlet.
The pump must be plugged to a grounded power outlet. Pump must be connected to a
motor protection switch (Residual Current Circuit Breaker - MCCB).
3.
Install a relay switch. Do not install it in parallel with heavy inductance load (for
example: engines). See fig. 10.
WIRING
P
- Dosing pump
R
- Relay
I
- Switch or safety device
E
- Electrovalve or inductance load
A
- Power supply
Fig. 10. Electrical installation.
4.
Verify peak Amps. 115 or 230 VAC pumps do not use motor overload protection.
Power supply
12 VDC
connect the pump to a 55 Ah-12VDC battery
24 VDC
connect the pump to a 200W stabilized power supply (verify
peak Amps)
5.
Verify level probe “BNC” is connected as described in
⎘
“
Foot filter / Level probe”..