Records
Maintenance (expert)
31
3.6
Maintenance (expert)
Maintenance is required at least every 2 years or when requested by the control system. We recommend you
perform maintenance annually.
Comments:
Tasks
Notes
Emptying ash bin
•
Emptying ash bin
•
Check the seals
Clean the piping
•
Clean the piping between the boiler, precipitator and chimney
Clean the precipitator
•
Check and remove ash accumulations
•
Clean the flushing air opening
•
Clean and inspect the electrode holder
•
Check the alignment of the electrodes
•
Check maintenance cover seal
Check flaps
•
Check the drive chain of the flaps
•
Check the positions of the flaps and position switch
•
Check the seals on the flaps
Check the electrode cleaning
•
Check the drive chains and position switches of the electrode dedusting
•
Check idle position of the electrode dedusting
•
Checking the ease of movement of the striking mechanisms
Check de-ashing
•
Check the drive chains and position switches of the electrode dedusting
•
Check the drive chains and the position switches of both sliding rakes
Clean flushing air fan
Check the safety switch for the maintenance cover
Check the safety switch for the ash bin
performed on: _________________________
performed by: _________________________