![eta BE-P3 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/eta/be-p3/be-p3_installation-manual_2430221009.webp)
Installation
Exchange for HACK, SH, PE-K
9
3.2
Exchange for HACK, SH, PE-K
Technical illustrations
The following describes how to exchange the control
panel of the wood chip boiler and is also applicable to
the HACK and PE-K boilers.
Dismantle defective control panel
Remove the cover plate on the inside of the insulation
door.
Fig. 3-8: Cover plate
Remove the four screws on the side and carefully take
the cover with the control panel out of the top.
Fig. 3-9: Cover
Disconnect the earthing cable of the cover from
the insulation door terminal.
Fig. 3-10: Earthing
Disconnect all lines on the control panel. Unscrew the
attachment nuts and remove the defective control
panel.