Installation
Adjusting the log boiler
15
Detaching the side panel
Remove the side panels of the log boiler on which the
pellet burner will be installed later on.
Fig. 4-8: Removing the side panel
If the actuators are located on the same side,
label them (with "top" and "bottom" for example)
and then remove them.
Fig. 4-9: Removing the actuators (if required)
Change mounting side of actuators
The air valve actuators must be located on the
side of the log boiler on which the pellet burner is
not
installed.
If the actuators are located on the same side the pellet
burner will be installed, the mounting side of the
actuators must be changed. To do this, carry out the
following steps.
1. Remove the lower bracket from the side on which
the pellet burner will be installed later. This bracket
is no longer needed.
Fig. 4-10: lower bracket
2. Pull the washer and the spring from the lower air
box (secondary air) off the axle.
Fig. 4-11: Washer and spring
Do not discard the spring. It will be required
on the opposite side.