![Esu SwitchPilot 3 Plus Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/esu/switchpilot-3-plus/switchpilot-3-plus_instruction-manual_2429803006.webp)
6
4.4. Operating modes
The SwitchPilot 3 Plus has a total of 16 transistor outputs, which
are grouped in 8 output pairs 1 to 8. Each output pair contains
two outputs (Out A and Out B) and can be configured individually
to suit the desired application. The following operating modes are
possible:
4.4.1. Pulse operation
If the output is configured for pulse operation, the output is swit-
ched on as soon as an appropriate command is received. At the
same time, a timer automatically turns off the output as soon as a
predetermined time (pulse time) saved in the decoder has elapsed,
even if the button (on the command station or control panel) has
been released beforehand.
Operating modes
If the button is pressed longer than the pre-determined pulse time,
the output will still be switched off.
Limiting the switch-on time prevents accessories to blow. Optio-
nally, the output can also be slowly dimmed up and dimmed down
(so-called „zoom” for incandescent lamp simulation).
The pulse operation is the default setting of the SwitchPilot 3 Plus
and is ideal for controlling solenoid turnout drives.
Some DCC command stations (e.g.: by Lenz) repeat the power
command in a fixed rhythm until the button is released. With each
power-on command received, the SwitchPilot 3 Plus resets the
stopwatch. This is shown in Fig. 1.
Figure 1: Pulse operation
keyboard
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15 16
time
on
off
1
RED
ON
1
RED
OFF
1
(RED
ON)
(Lenz)
Impulse-Time
1
RED
ON
1
RED
OFF
Impulse-Time
1
RED
ON
1
RED
OFF
Impulse-Time
Содержание SwitchPilot 3 Plus