Esu SwitchPilot 3 Plus Скачать руководство пользователя страница 24

24

11. RailCom® 

RailCom® is a technique for transferring information from the de-

coder back to the command station. When RailCom® is switched 

on, the CV values of the SwitchPilot can be read out directly on 

the main. From the factory, RailCom® is active on SwitchPilot 3.

11.1. RailCom® Configuration 

If necessary, RailCom® can be disabled on the SwitchPilot.

In this case „Mode” must be set to „Disabled”. The value of CH2 

is intended for future expansions and should not be changed.

RAILCOM

Mode    : Enabled

CH2     : Enabled

 

RESET DECODER

Do Reset: 

Yes

 

RailCom®

12. Reset to factory default (decoder reset)

You can restore the decoder‘s factory default settings at any time.

12.1. With the programming button

•  Disconnect the power supply to the SwitchPilot 3 Plus decoder. 

The display must go out.

• Press and hold the 

PROG/OK

 button.

• Reconnect the power supply for the decoder. The decoder will be 

reset to factory default values.

• Release the 

PROG/OK

 button. The turnout numbers are now 

flashing because the SwitchPilot 3 expects to assign new turnout 

numbers (as described in chapter 6.1.).

• Confirm the turnout numbers with 

PROG/OK

 or first assign the 

new turnout numbers with (+) or (-).

12.2. With DCC systems

To do this, write the 

value 8 in CV 8

 either via POM (wiring as per 

chapter 8) or on the programming track (wiring as per chapter 9). 

The display of the SwitchPilot 3 Plus briefly goes dark, after which 

the factory values are restored.
Writing in CV 8 is a special case, so some command stations may 

display an error „err02” or similar. However, the SwitchPilot will 

accept the command.

12.3. With the display

The „RESET DECODER” panel on the display enables you to resto-

re the factory default values directly.

• In the “Do Reset” option, select „Yes” and confirm with 

PROG/ 

OK

. The display will flicker briefly, after which the SwitchPilot will 

be restored to have factory default values again.

Содержание SwitchPilot 3 Plus

Страница 1: ...Instruction manual 2 Edition May 2021 P N 01721 24977 From Decoder Firmware 3 0 9 51831 SwitchPilot 3 Plus SwitchPilot 3 Plus SWitch Pilot...

Страница 2: ...ationship accessory addresses turnout numbers 16 6 1 1 Assigning turnout numbers 17 6 2 Introduction to the operating structure 18 6 3 Address mode for ROCO command stations 19 6 4 Configuring outputs...

Страница 3: ...tt dienen Lieferm glichkeiten und alle sonstigen Rechte vorbehalten Elektrische und mechanische Ma angaben sowie Abbildungen ohne Gew hr Jede Haftung f r Sch den und Folgesch den durch nicht bestimmun...

Страница 4: ...the decoder Therefore a request Please carefully work through this manual prior to commissioning Although all SwitchPilot decoders are very robust a wrong con nection could destroy the device If in do...

Страница 5: ...motive commands instead of the re quired accessory commands For simplifying the rather cumbersome configuration of accesso ry decoders the SwitchPilot 3 Plus has an innovative operating concept consis...

Страница 6: ...ased beforehand Operating modes If the button is pressed longer than the pre determined pulse time the output will still be switched off Limiting the switch on time prevents accessories to blow Optio...

Страница 7: ...y action mode In K83 mode the output remains active until the button on the command station or control panel is released This operating mode is suitable for turnout drives with end position shutdown o...

Страница 8: ...t B behave like a change over switch Optionally the output can also be slowly dimmed up and dimmed down so called zoom for incandescent lamp simulation The K84 operation is well suited for lighting ap...

Страница 9: ...with the command Di verging Red Optionally the output can also be slowly dimmed up and dimmed down so called zoom for incandescent lamp simulation The alternating flasher operation is ideal for illum...

Страница 10: ...up ply We recommend an external power supply particularly for larger layouts because then the energy for powering the drives does not add to the load for the command station or booster c Connect the T...

Страница 11: ...f your command station For more information see Chapter 9 5 3 External power supply For larger layouts with many electric loads we recommend the use of an external power supply DC and AC power supplie...

Страница 12: ...on your command station respectively con trol panel diverging and straight route are reversed please swap the wires at terminals Out A and Out B The power consumption of PECO switch drives is so high...

Страница 13: ...is as shown in Fig 8 Terminal 8 You can use either Terminal Out A or Out B depending on whether you want to activate the uncoup ler with the diverging or straight turnout button 5 5 Connecting the Sw...

Страница 14: ...ized turnout drives Motorized turnout drives can be controlled with the help of the SwitchPilot Extension module Reversing the operating voltage of the electric motor changes the direction of rotation...

Страница 15: ...easy Wiring the outputs 5 5 3 LGB Turnout drive The wiring is as shown in Fig 11 Unless reprogrammed the mo tors are supplied with electricity for approx 520 msec and are then switched off to prevent...

Страница 16: ...stations and or throttles respectively central units support POM for accessory decoders or forgotten addresses of decoders installed on the layout Even assigning the decoder address presented many mod...

Страница 17: ...red turnout numbers for outputs 1 to 4 The currently selected turnout numbers are displayed flashing e Press the PROG OK button again to confirm the turnout numbers for outputs 1 to 4 The display no l...

Страница 18: ...the and buttons you can scroll between the individual panels a Name of the panel b Name of setting option 1 c Value of the setting option 1 d Name of setting option 2 e Value of the setting option 2 f...

Страница 19: ...e standard setting use a different computation method to calculate the turnout num bers from the accessory addresses Set the decoder to ROCO to ensure that the SwitchPilot 3 Plus handles instructions...

Страница 20: ...uts is also displayed If the SwitchPilot 3 Plus is powered directly by the command sta tion Voltage displays the digital track voltage otherwise the voltage of the connected power supply FADEIN FADEOU...

Страница 21: ...It may remain wired as shown in chapter 5 2 respectively 5 3 8 2 Reading and writing CVs with POM Select POM as well as Accessory decoder on your command station Make sure that the correct accessory a...

Страница 22: ...t support the POM mode for accessory decoders but only for mobile locomotive decoders In this case configure the SwitchPilot directly using its display 9 Configuration with the programming track In so...

Страница 23: ...001 0004 will flash inversely Press the PROG OK button again so that the turnout numbers for the second group ex works 0005 0008 flash inversely Now switch a solenoid of your choice to the digital cen...

Страница 24: ...r supply for the decoder The decoder will be reset to factory default values Release the PROG OK button The turnout numbers are now flashing because the SwitchPilot 3 expects to assign new turnout num...

Страница 25: ...case we ask you to make these available to us either in our support forum or to contact us by e mail We also provide a telephone hotline which should only be used in the case of really special reques...

Страница 26: ...de IMPULSE PECO K83 K84 AltFlash Time 130 ms 195 ms 2015 ms Zoom Disabled Enabled 05 OUTPUT MODE 3 Mode Impulse Time 520ms Zoom Disabled Mode IMPULSE PECO K83 K84 AltFlash Time 130 ms 195 ms 2015 ms Z...

Страница 27: ...CO K83 K84 AltFlash Time 130 ms 195 ms 2015 ms Zoom Disabled Enabled 11 FADEIN FADEOUT Time 65 ms Time 0 ms 65 ms 4160 ms 12 RAILCOM Mode Enabled CH2 Enabled Mode Enabled Disabled CH2 Enabled Disabled...

Страница 28: ...6 127 128 32 32 0 129 130 131 132 33 33 0 Turnout numbers Address CV1 CV 9 133 134 135 136 34 34 0 137 138 139 140 35 35 0 141 142 143 144 36 36 0 145 146 147 148 37 37 0 149 150 151 152 38 38 0 153 1...

Страница 29: ...05 406 407 408 102 38 1 409 410 411 412 103 39 1 413 414 415 416 104 40 1 417 418 419 420 105 41 1 421 422 423 424 106 42 1 425 426 427 428 107 43 1 Turnout numbers Address CV1 CV 9 429 430 431 432 10...

Страница 30: ...ive Duty cycle multiple of 130 ms 32 63 Continuous bis tableoperation K84 compatible Either Out A or Out B active permanent output 64 4 Configuration Output 2 Defines the properties of decoder output...

Страница 31: ...oom when switched on off Zoom means slowly fading in or out of the function This can be used to create a prototypical cross fading of light signals 0 255 0 Bit Description Value 0 Zoom function active...

Страница 32: ...64 8 Function Description Value As CV 3 39 Configuration output 6 Defines the properties of decoder output 6 0 64 8 Function Description Value As CV 3 40 Configuration output 7 Defines the properties...

Страница 33: ...report card as detailed and precise as possible and return it with your faulty product Please use the appropriate postage when shipping to ESU Extend of warranty exclusions This warranty covers free...

Страница 34: ...34 Change history 18 Change history 1 Edition December 2020 Initial Document 2 Edition March 2021 Spelling mistake corrected...

Страница 35: ...35...

Страница 36: ...Phone Date Signature 2 Error Transistor outputs Short circuit Servo outputs No function from the start No Function Programming on the Main 3 Error description 4 Receipt Please enclose your receipt in...

Отзывы: