IGNEO
touch
user manual
3.7 B
UFFER
To enter the buffer menu, press the button number ''7''
on main menu and choose ''BUFFER''
3.7.1 SETTINGS
NAME
DESCRIPTION
Min. temp. (top) [
°
C]
Start heating the buffer if temperature drops below this point.
Max. temp. (bottom) [
°
C]
Stop heating the buffer if temperature raises above this point.
3.8 S
OLAR
HEATING
To enter the solar heating menu, press the button number
''7'' on main menu and choose ''SOLAR HEATING''.
3.8.1 SETTINGS
NAME
DESCRIPTION
Flow (l/min)
Flow rate in solar installation. This parameter is used to correctly calculate the
power.
Delta switch on [
°
C]
Solar heating pump is turned on when the temperature difference between the
solar collector and the water tank exceeds this value.
Delta switch off [
°
C]
Solar heating pump is turned off when the temperature difference between the
solar collector and the water tank falls below this value.
3.9 A
LARMS
The driver includes the history of alarms which is saved in
the memory. If there are any active or unconfirmed
alarms, on the main screen alarm icon will appear. On
pressing it, the history will be displayed, where the last 20
alarms are stored.
14
www.estyma.pl
EGP -EN 20171024