Chapter 3. Detailed description of screens/functions

3.5   H

OT

 

WATER

To enter the hot water menu on the main screen, press
number ''12''. 

There is current temperature and set target temperature,
as well as the chosen mode, displayed on the screen.

Also symbols for currently working system elements are visible.

3.5.1   SETTINGS

NAME

DESCRIPTION

Comfort temperature [

°

C]

The set hot water temperature in the comfort range in the time mode or the 
comfort mode. 

Economical temperature [

°

C]

The set hot water temperature in the economic range in the time mode or the 

economic mode. 

Heat now

One time hot water heating to the comfort temperature, regardless of the mode.

Hysteresis [

°

C]

The hot water heating starts when the temperature in the tank is lower than the 
set temperature minus hysteresis. 

Antilegionella

Enables weekly water heating to decrease the risk of legionella infection. The 
heating process starts at 1 a.m every wednesday.

Hot water priority

Sets Hot Water priority. C/H pump is not engaged when H/W is heated.

3.6   B

URNER

To go to the burner menu on the main screen, press ''9''.

Symbols for currently working system elements and the
burner status should appear.

3.6.1   SETTINGS

NAME

DESCRIPTION

Air correction [%]

Correction of air programmed by the instrallator for the burning process.

Min power [%]

Lower limit for burner power modulation.

Max power [%]

Upper limit for burner power modulation.

www.estyma.pl

13

 

EGP-EN 20171024

Содержание IGNEO Touch

Страница 1: ...User manual EG Pellet ...

Страница 2: ......

Страница 3: ...ting 7 2 1 5 SETTING THE TARGET BOILER TEMPERATURE program 8 2 1 6 FUEL FILLING setting the fuel level 8 2 2 Menu structure 9 Chapter 3 Detailed description of screens functions 10 3 1 Boiler 10 3 1 1 SET TARGET TEMPERATURE AND OPERATING MODE 10 3 1 2 SETTINGS 10 3 2 Schedules 11 3 3 Heating and hot water operation modes 12 3 4 Heating 12 3 4 1 SETTINGS 12 3 5 Hot water 13 3 5 1 SETTINGS 13 3 6 Bu...

Страница 4: ...en in the instruction manual Check if the device isn t dammaged When in doubt don t use the device and contact the retailer If you encouter situations not mentioned in the instruction manual or you are in doubt about safe usage of the device please contact the retailer Pay attention to any warning symbols on the device or packaging The device must be used in accordance with intended use The device...

Страница 5: ...s and local standards and regulations Additional safety devices must be used to protect the boiler and heating elements from eventual regulator malfunctions or software errors This device has no replaceable parts All servicing and repair apart from cleaning and circuit breaker replacement electrical grid disconnected and changing settings must be performed by an authorized profesionals Before any ...

Страница 6: ...k enter the burner menu button Lit lamp means the burner is working 10 11 Quick enter the heating menu button Lit lamp means the circuit is working 12 Quick enter the hot water menu button Lit lamp means that the water preparation is working 13 Advanced button Long press 3 sec turns the boiler off Lit lamp means that the boiler is working LED description LETTER DESCRIPTION A green Boiler It is lit...

Страница 7: ... possible to quickly turn on off change of the operating mode of certain heating system elements ATTENTION If there are more than two heating system circuits you should enter the menu and then go to the circuit number 3 and 4 to change the heating program 2 1 4 SUMMER only water heating To turn on summer mode heating only hot water circuit press the On Off button and move all the Heating sliders t...

Страница 8: ... 1 2 1 6 FUEL FILLING setting the fuel level The regulator was equipped with the ability to calculate the remaining fuel in the tank To make calculating possible each time after adding fuel you should set the amount of the fuel in the tank The amount is set by the buttons and or by the slider This screen also allows to turn on the fuel conveyor manually In case of comlete fuel depletion it allows ...

Страница 9: ...Chapter 2 Basic controller operation 2 2 MENU STRUCTURE www estyma pl 9 EGP EN 20171024 ...

Страница 10: ... there s no need to heat the water the temperature will be set to minimum of 7 C antifreeze mode and the boiler will turn on only when needed time manual The boiler temperature is set as in the manual mode but the boiler can work only in set time limits time automatic The boiler temperature is set as in the automatic mode but the boiler can work only in set time limits 3 1 2 SETTINGS NAME DESCRIPT...

Страница 11: ...ording to the set schedules for each day of the week separately After selecting a day the window with daily schedule will appear To select a program for a certain hour click or slide the hour dial setting the time and press the eco or comf button After setting the program slider moves to another hour The regulator is equipped with a convenient function of copying the mode for other days of the wee...

Страница 12: ... temperature in the room in the comfort range with the time mode or the comfort mode Economical temperature C Set temperature in the room in the economic range with the time mode or the economic mode Hysteresis C The accuracy of maintaining the set target temperature in the room It may also affect the frequency of the boiler inset If the hysteresis is higher the burner turns on with lower frequenc...

Страница 13: ...the comfort temperature regardless of the mode Hysteresis C The hot water heating starts when the temperature in the tank is lower than the set temperature minus hysteresis Antilegionella Enables weekly water heating to decrease the risk of legionella infection The heating process starts at 1 a m every wednesday Hot water priority Sets Hot Water priority C H pump is not engaged when H W is heated ...

Страница 14: ...w rate in solar installation This parameter is used to correctly calculate the power Delta switch on C Solar heating pump is turned on when the temperature difference between the solar collector and the water tank exceeds this value Delta switch off C Solar heating pump is turned off when the temperature difference between the solar collector and the water tank falls below this value 3 9 ALARMS Th...

Страница 15: ......

Страница 16: ...Produced by estyma electronics al Lipowa 4 11 500 Giżycko POLAND tel 48 87 429 86 75 fax 48 87 429 86 75 biuro estyma pl www estyma pl ...

Отзывы: